Acta Chir Orthop Traumatol Cech. 1995; 62(3):142-154

[External fixation in complicated fractures of the femur.].

J Stehlík, J Bartonícek, J Váchal
Ortopedická klinika 3. lékarské fakulty KU, Praha.

This work demonstrates the results of treatment of 14 patients with complicated injury of the femur. In all cases external fixation, type Poldi 7 was used. Of great importance from the viewpoint of treatment is the following: - proper revision with sequestrectomy and resec tion of necrotic fragments; - exact technics of aplication the external fixation; - adequate stabilisation of the modification of de vices; - necessity the changes between the type modifica tions Poldi 7 devices; - early and usually repeated cancellous bone graf ting. The evaluation shows the difficulty of treatment and also longterm healthy, social and famillies consequences. Key words: fractures and pseudoarthrosis of the femur, external fixation, Poldi 7 devices.

Zveřejněno: 1. leden 1995  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Stehlík J, Bartonícek J, Váchal J. [External fixation in complicated fractures of the femur.]. Acta Chir Orthop Traumatol Cech. 1995;62(3):142-154. PubMed PMID: 20470498.
Stáhnout citaci