Acta Chir Orthop Traumatol Cech. 2008; 75(6):436-442 | DOI: 10.55095/achot2008/081
Clinical Evaluation of the Ceramic Femoral Component Used for Reconstruction of Total Knee ReplacementOriginal papers
- 1 I. ortopedická klinika 1.LF UK a FN Motol, Praha
- 2 Medin Orthopaedics, a. s., Praha
PURPOSE OF THE STUDY:
The study evaluates mid-term results of total knee replacement with a zirconia ceramic (ZrO2) femoral component.
MATERIAL:
The evaluated group comprised 20 knees in 19 patients (4 men and 15 women). In one patient the replacement was performed bilaterally. Two patients had in the contralateral knee the same type of prosthesis with a femoral chrome-cobalt component.The mean age at the time of operation was 65.2 years (range, 38-81 years). The primary indication was 14times osteoarthritis and 5times rheumatoid arthritis. The average follow-up period was 6.5 years (range, 2.1-8.5 years).
METHODS:
Patients included in the study regardless of age, body mass and the basic diagnosis, agreed with the use of the ceramic femoral component. The evaluation covered a range of motion, mechanical axis, joint stability, pain, swelling, ability to walk on level ground and on stairs, subjective satisfaction (EULAR Knee Chart). Radiograph were assessed at one year intervals in two projections to identify the incidence of radiolucency around the implant. The Kaplan-Meier survival curve was used and compared with the survival curve in identical chrome-cobalt implants.
RESULTS:
At he final follow-up, 14 knees were evaluated, because 3 patients died without any connection with the implant, in one case the tibial component migrated due to necrosis of the tibial condyle in a patient with RA and two implants had to be revised and replaced due to polyethylene wear. No infection or negative tissue reaction was recorded in the evaluated group. The average flexion range was 109 degrees. All knees were stable and without swelling, in two cases there occurred slight femoropatellar pain. Twelve patients were fully satisfied, 2 patients were satisfied with a certain reservation. The diferences in the course of the survival curves of chrome-cobalt and ceramic implants were statistically insignificant.
DISCUSSION:
Although the use of zirconia ceramics in vitro reduces the amount of polyethylene wear, the clinical outcomes of total knee replacements as compared to the hip are not convincing. One of the causes may be the substantially different and more complex biomechanics of the knee. Tribology improvement of the femoral ceramic component cannot compensate the deficiencies in the joint balancing in flexion and extension. The economically and technlogically demanding production of these implants may be justified in patients with allergies caused by chrome-cobalt components.
CONCLUSIONS:
The results of mid-term follow-up of the use of zirconia ceramic femoral components proved no impact on the improvement of the period of survival of the knee implant. No adverse response to the material or mechanical failure of the ceramic components was encountered.
Keywords: total knee replacement, zirconia ceramic femoral component, TKR mid-term results, ceramic knee survival curve
Accepted: August 12, 2008; Published: December 1, 2008 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- BEK, J., VAVŘÍK, P., LANDOR, I.: Hodnocení přežití náhrady kolenního kloubu Walter-Motorlet - dlouhodobé výsledky. Acta Chir. orthop. Traum. čech., 72: 221-227, 2005.
- DONÁT, A., KONVIČKOVÁ, S.: Biomechanics of the Ceramic Knee Replacement. Med. Biol. Eng. Comput., 37: 314-316, 1999.
Go to original source...
Go to PubMed...
- DANĚK, J., DENK, F., HLAVÁČEK, I., NEDOMA, J., STEHLÍK, J.,VAVŘÍK, P.: On the Stress-Strain Analysis of the Knee Replacement. In: Lagana, A.; Gavrilova, M. L.; Kumar, V.; Mun, Y.; Tan, C. J. K.; Gervasi, O. (eds.): Lecture Notes in Computer Science. Vol. 3044: Heidelberg, Springer Verlag 2004, 456-466.
Go to original source...
- DANĚK, J., NEDOMA, J., HLAVÁČEK, I., VAVŘÍK, P., DENK, F.: Numerical modelling of the weight-bearing total knee joint replacement and usage in practice. Math. Comput. Simul. 76: 49-56, 2007.
Go to original source...
- KUČERA,T., URBAN, K., KARPAŠ, K., ŠPONER, P.: Omezení hybnosti kolenního kloubu po implantaci totální endoprotézy. Acta Chir. orthop. Traum. čech., 74: 326-331, 2007.
Go to original source...
- NAKAMURA, T., OONISHI, E.,YASUDA, T., NAKAGAWA, Y.: A new knee prosthesis with bisurface femoral komponent made of zirconia ceramic (report 2). Key Eng. Mat., 254-256:607-610, 2004.
Go to original source...
- NEDOMA, J., HLAVÁČEK, I., DANĚK, J., VAVŘÍK, P., STEHLÍK, J., DENK, F.: Some recent Results On a Domain Decomposition Method in Biomechanics of Human Joints. In: Kumar, V., Gavrilova, M. L., Tan, C. J. K (eds.): 3 Lecture Notes in Computer Science. Vol. 2667: Heidelberg, Springer Verlag 2003, 587-600.
Go to original source...
- OKA, M., KUMAR, P., IKEUCHI, T. et al.: Low wear rate of UWHMPE against zirconia ceramic. Bioceramics, 5: 373-379, 1992.
- OONOSHI, H., MURATA, N., SAITO, M., et al.: 3 to 18 Year Clinical Results of Total Knee Replacement with Ceramic Components. Key Eng. Mat. 192-195: 999-1002, 2001.
Go to original source...
- PAYTEN, M.W., BEN-NISSAN, B.: Development of a modular ceramic knee prosthesis. In: Wise, D. L., Trantolo, D. J., Lewandrowski, K. U., Gresser, J. D., Cattaneo, M. V., Yaszemski, M. J. (eds): Biomaterials Engineering and Devices. Human applications. New Jersey, Humana Press 2000, 309-336
Go to original source...
- POKORNÝ, D., JAHODA, D., TOMAIDES, J., VAVŘÍK, P., LANDOR, I., SOSNA, A.: Sedmileté klinické výsledky systému totální náhrady kolenního kloubu SVL / Beznoska. Acta Chir. orthop. Traum. čech., 72: 277-281, 2005.
- POKORNY, D., SLOUF, M., SOSNA, A., ENTLICHER, G., VAVRIK, P., LANDOR, I., JAHODA, D.: New methods of UHMWPE wear particles evaluation in granuloma around THR 8th EFORT Congress, Florence 2007.
- RYBKA, V., VAVŘÍK, P., LANDOR, I.: Assessment of the Walter-Motorlet cemented condylar knee replacement - 100 cases. J. Orthop. Rheumatology, 4: 71-81,1991.
- ROZKYDAL, Z., JANÍK, P., JANÍČEK, P., KUNOVSKÝ, R.: Revizní náhrada kolena po aseptickém uvolnění. Acta Chir. orthop. Traum čech., 74: 5-13, 2007.
Go to original source...
- SIDA, D., BLAISE. L., SIDA, V., VAVRIK, P.: Zirconia ceramic femoral components. Key Eng. Mat., 218: 581-584, 2002.
Go to original source...
- ŠÍDA, V.: Zpráva o průběhu a výsledcích řešení projektu: "Kondylární náhrada kolenního kloubu s aplikací keramiky." č. PPZ1/29/98. DIAS a. s., Turnov, 1998.
- SOSNA, A., RADONSKÝ, T., POKORNÝ, D., VEIGL, D., HORÁK, Z., JAHODA, D.: Polyetylénová choroba. Acta Chir. orthop. Traum. čech., 70:6-16, 2003.
- SPECTOR, M., RIES, M. D., Bourne, R. B., SAUER, S. W., LONG, M., HUNTER, G.: Wear performance of ultra-high molecular weight polyethylen on oxidized zirkonium total knee femoral components. J. Bone Jt Surg., 83-A: 80-86, 2001.
Go to original source...
Go to PubMed...
- UENO, M., APGAR, M., SARIN, V.: Mechanical stress analysis and burst testing of a zirconia femoral component for total knee arthroplasty. Key Eng. Mat., 218 - 220: 573 - 576, 2002.
Go to original source...
- VAVŘÍK, P., LANDOR, L: Revision TKA in the cases with severe polyethylene wear. Sborník přednášek: X. Národní kongres ČSOT s mezinárodní účastí, 18. 5. 2006, Praha.
- VAVŘÍK, P., POPELKA, S., VÍRAVA, J.: Ojedinělý případ oboustranného výskytu rozsáhlého polyetylenového granulomu po náhradě kolena. Acta Chir. orthop. Traum. čech., 68: 320-323, 2001.
- VAVŘÍK, P. VEIGL, D.: Uvolnění a periprotetická osteolýza kloubních náhrad. Čes. Revmatol., 10: 157-164, 2002.
- VEIGL, D., NIEDERLOVÁ, J., KRYŠTŮFKOVÁ, O.: Periprosthetic osteolysis and its association with the molecule RANKL expression. Physiol. Res., 56: 455-62, 2007.
Go to original source...
Go to PubMed...
- WALKER, P.: Questions & Answers: Wear in Knees. Tribology in Orthopaedics, 3: 10-11, 2008