Acta Chir Orthop Traumatol Cech. 2009; 76(3):172-178 | DOI: 10.55095/achot2009/033
Long-Term Experience with the Combined ARBOND Hydroxyapatite Coating in Implant OsteointegrationOriginal papers
- I. ortopedická klinika 1.LF UK, FN Motol, Praha
PURPOSE OF THE STUDY:
The hydroxyapatite coating of an implant surface provides osteoactive conditions that can support osteointegration of cementless joint arthroplasties. However, the possibilities of hydroxyapatite degradation, resorption and delamination that may become responsible for failure of total hip arthroplasty (THA) have been reported. The aim of the study was to assess the properties of Arbond hydroxyapatite coating by comparing the long-term survival of implants identical in construction but different in surface coating.
MATERIAL:
One group (HA) comprised 86 patients (100 THAs) with an average age of 45.14 years (range, 22.3 to 77.4 years) at the time of surgery who received a femoral stem (Walter) with a coating of Arbond sprayed over the proximal half. The other group (control) included 92 patients (100 THAs) with an average age of 49.7 years (range, 33 to 68.7) who had an identical femoral component without coating. In both groups the conical-shaped acetabular cup (Walter) and femoral head made of sintered ceramics were used.
The patients in whom one or both components were replaced or extracted were not included in the final clinical evaluation (Harris Hip Score). For the statistical analysis of survival, a stable component still in place at the date of the revision procedure was regarded as surviving; a lose component at the same date was considered a failure. Finally, 71 hips of the HA group followed up for an average of 15.51 (range, 5.6 to 18.56) years and 39 control hips at an average follow-up of 14.19 (range, 6.24 to 18.48) years were clinically evaluated. The data of patients who died in the course of study (HA group, 11; control group, 14) were included in the clinical evaluation with the date of their last follow-up.
METHODS:
For both groups, the Kaplan-Meier survival curves were constructed for overall survival and for the survival of acetabular and femoral components separately. Differences in survival curves were evaluated with the use of Gehan's Wilcoxon test. Component survival was also calculated using 15-year life-table survivorship analysis. Differences in variables under study were assessed with the use of the two-tailed Student's t-test. A p value of less than 0.05 was considered significant.
RESULTS:
A total of 29 % hips were revised in the HA group, 27 % for aseptic loosening of the acetabular cup, in 2 % both components were removed because of deep infection. In the control group revision procedures were performed in 61 % of the hips. Except for one case of deep infection (1 %), the reason was cup loosening in 30 %, stem loosening in 12 % and both components loosening in 18 % of the hips. The HA group showed a significantly longer survival of both total hip prostheses and individual components. The final HHS was significantly better than the initial score in both groups. There was no difference in the degree of improvement between the two groups. The radiographic data showed full osteointegration of stems in the HA group. The control group, on the other hand, had 87 % of the stems with translucent lines in zone I and zone VII according to Gruen's classification.
DISCUSSION:
The significantly longer survival of hips in the HA group gives support to the use of hydroxyapatite coating in total hip arthroplasty. The poorer results in grit-blasted implants, as compared with the literature data, can be explained by alow degree of roughness of the Walter implant surfaces.
CONCLUSIONS:
The combined Arbond hydroxyapatite coating improves conditions for implant osteointegration in the bone.
Keywords: osteoactive surface, hydroxyapatite, cementless, THA, osteointegration
Published: June 1, 2009 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- ALDINGER, P. R., BREUSH, S. J., LUKOSCHEK, M., MAU, H., EWERBECK, V., THOMSEN, M. A: A ten-to 15 year follow-up of the cementless Spotorno stem. J. Bone Jt Surg., 85-B: 209-214, 2003.
Go to original source...
Go to PubMed...
- ALDINGER, P. R., THOMPSEN, M., MAU, H, EWERBECK, V., BREUSH, S. J: Cementless Spotorno tapered titanium stems. Excellent 10-15 year survival in 141 young patiens. Acta orthop. scand., 74: 253-258, 2003.
Go to original source...
- BLOEBAUM, R. D., DUPONT, J. A: Osteolysis from a press-fit hydroxyapatite coated implant: a case study. J. Arthroplasty, 8:195-202, 1993.
Go to original source...
Go to PubMed...
- CAPELLO, W. N., D ANTONIO, J. A., MANLEY MT, FEINBERG, J. R: Hydroxyapatite in total hip arthroplasty. Clinical results and critical issues. Clin. Orthop., 355: 200-211, 1998.
Go to original source...
- COATHUP, M. J., BLUNN, G. W., FLYNN N., WILLIAMS, C., THOMAS, N. P: A comparison of bone remodelling around hydroxyapatite-coated, porous-coated and grit-blasted hip replacements retrieved at post-mortem. J. Bone Jt Surg., 83-B: 118-123, 2001.
Go to original source...
- D ANTONIO, J. A., CAPELLO, W. N., MANLEY, M. T: Remodeling of bone around hydroxyapatite-coated femoral stems. J. Bone Jt Surg., 78-A: 1226-1234, 1996.
Go to original source...
Go to PubMed...
- D ANTONIO, J. A., CAPELLO, W. N., MANLEY, M. T, GEESINK, R: Hydroxyapatite femoral stems for total hip arthroplasty: 10-13-year follow-up. Clin. Orthop., 393: 101-111, 2001.
Go to original source...
Go to PubMed...
- DE GROOT, K., GEESINK,R., KLEIN, C. P., SEREKIAN, P: Plasma-sprayed coatings of hydroxyapatite. J. Biomed. Mat. Res., 21: 1375-1381, 1987.
Go to original source...
Go to PubMed...
- DELAUNAY, C., KAPANDJI, A. I: Survival analysis of cementless grit-blasted titanium total hip arthroplasties. J. Bone Jt Surg., 83-B: 408-413, 2001.
Go to original source...
- FOUSEK, J., INDRÁKOVÁ, P: Totální endoprotéza kyčelního kloubu u postdysplastické koxartrózy: Má typ jamky a její umístění vliv na životnost endoprotézy? Acta Chir. orthop. Traum. čech., 74: 47-54, 2007.
Go to original source...
Go to PubMed...
- GALLO, J., MRÁZEK, F., PETŘEK, M: Podíl imunogenetických faktorů na vzniku a rozvoji periprotetické osteolýzy. Acta Chir. orthop. Traum. čech., 74: 247-252, 2007.
Go to original source...
- GEESINK, R. G. T., HOEFNAGELS, N. H. M: Six-year results of hydroxyapatite-coated total hip replacement. J. Bone Jt Surg., 77-B: 534-547, 1995.
Go to original source...
- GEESINK, R. G. T., MANLEY, M. T: Hydroxyapatite coatings in orthopaedical surgery. New York, Raven 1993.
- GOMEZ-VEGA, J. M., SAIZ, E., TOMSIA, A. P: Glass-based coatings for titanium implant alloys. J. Biomed. Mat. Res., 46: 549-559, 1999.
Go to original source...
- GROSS, K. A., WALSH, W., SWARTS, E: Analysis of retriever hydroxyapatite-coated hip prostheses. J. Therm Spray Technol., 13:190-199, 2004.
Go to original source...
- GRUEN,T. A., MCNEICE, G. M., AMSTUTZ, H. C: Modes of failure of cemented stem-type femoral components: a radiographic analysis of loosening. Clin. Orthop., 141: 17-27, 1979.
Go to original source...
- HAHN, H., PALICH, W: Preliminary evaluation of porous metal surfaced titanium for orthopedic implants. J. Biomed. Mat. Res., 4: 571-577, 1970.
Go to original source...
Go to PubMed...
- KOVANDA, M., HAVLÍČEK, V., HUDEC, J: Předčasné aseptické uvolňování dříku CF- 30. Acta Chir. orthop. Traum. čech., 74: 59-, 2007.
Go to original source...
- MASÁR, J: 10-ročné skúsenosti s individuálnou TEP podľa Aldingera - zhodnotenie výsledkov. Acta Chir. orthop. Traum. čech., 74: 175-, 2007.
Go to original source...
- MOUZIN, O., SOBALLE, K., BECHTOLD, J.E: Loading improves anchorage of hydroxyapatite implants more than titanium implants. J. Biomed. Mat. Res. Appl. Biomater., 58: 61-68, 2001.
Go to original source...
- OOSTERBOS, C. J. M., RAHMY, A. I. A., TONINO, A. J., WITPEERD, W: High survival rate of hydroxyapatite-coated hip prostheses. Acta orthop. scand., 75: 127-133, 2004.
Go to original source...
Go to PubMed...
- ROKKUM, M., REIGSTAD, A., JOHANSSON, C. B: HA particles can be released from well-fixed HA-coated stems. Histopathology of biopsies from 20 hips 2-8 years after implantation. Acta orthop. scand., 73: 298-306, 2002
Go to original source...
Go to PubMed...
- ROKKUM, M., REIGSTAD, A., JOHANSSON, C. B., ALBREKTSSON, T: Tissue reactions adjacent to well-fixed hydroxyapatite-coated acetabular cups. J. Bone Jt Surg., 85-B: 440-447, 2003
Go to original source...
Go to PubMed...
- ROTHMAN, R. H., HOZACK, W. J., RANAWAT, A., MORIARTY, L: Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants. J. Bone Jt Surg., 78-A: 319-324, 1996.
Go to original source...
Go to PubMed...
- SHARMA, D. K., BROOKS, S., CREASEY, S., LEWIS, B: (2004) Fracture of fully hydroxyapatite-coated femoral stem of total hip replacement-a report of 3 cases. Acta orthop. scand., 75: 768-771, 2004.
Go to original source...
Go to PubMed...
- SUN, L., BERNDT, C. C., GROSS, K. A., KUCUK,A: Material fundamentals and clinical performance of plasma-sprayed hydroxyapatite coatings: a review. J. Biomed. Mat. Res., 58: 570-592, 2001.
Go to original source...
Go to PubMed...
- THEIS, J. C., BALL, C: Medium-term results of cementless hydroxyapatite-coated primary total hip arthroplasty: a clinical and radiological review. J. Orthop. Surg., 11:159-165, 2003.
Go to original source...
Go to PubMed...