Acta Chir Orthop Traumatol Cech. 2009; 76(4):281-287 | DOI: 10.55095/achot2009/052
Dlouhodobé výsledky CLS dříku u primární náhrady kyčlePůvodní práce
- I. ortopedická klinika LF MU v Brně, FN u sv. Anny, Brno
PURPOSE OF THE STUDY:
The aim of the study was to evaluate the results of primary total hip arthroplasty with the use of the CLS stem at 11 to 17 years after implantation.
MATERIAL AND METHODS:
A total of 108 patients (122 hips) in whom a CLS stem was used in the 1991-1996 period were evaluated. The group included 34 men and 74 women, with an average age of 48 years (range, 28-63). The CLS stem with a neck-shaft angle of 145° and the CLS expansion cup were used in all patients. Clinical outcomes were evaluated by Merle d'Aubigné-Postel score and Harris hip score, radiological examination was completed on AP and lateral views of the pelvis and the operated hip.
RESULTS:
The average follow-up was 16.4 years (range, 11-17). The average Merle d'Aubigné-Postel score was 14.5 (range, 13.9-17.0) points and the average Harris hip score was 84.8 (range, 70-99) points. Very good or good outcomes were found in 81% of the patients. Three patients underwent revision surgery, in one for septic loosening, in one for aseptic loosening and in one for varus stem position leading to instability. The radiographs evaluated as described by Engh showed 116 stable stems, three fibrous stable and three unstable stems. Subsidence of more than 3 mm, without any further deterioration, was found in five hips at 12 months post-operatively. Seven hips showed one radiolucent line, four showed two radiolucent lines and three hips showed three radiolucent lines, all of them being less than 2 mm wide.
DISCUSSION:
Radiographic evidence of a stable stem in 116 hips (116/122) suggests a high reliability of the implant. Assessment of radiolucent lines showed 108 hips without radiographic demarcation and 11 hips with slight demarcation. The signs of stress-shielding grade 1 were found in 28 hips. Good results of arthroplasty with the CLS stem can be attributed to its three-dimensional wedge-shaped design that allows for an optimal press-fit in the metaphyseal region. The porous surface provides reliable osteointegration. Stress-shielding is prevented by optimal stress distribution in the metaphyseal region and by a modulus of elasticity of titanium alloy which closely approximates the modulus of elasticity of bone.
CONCLUSIONS:
At 15 years post-operatively, the cumulative probability of clinical survivorship of the CLS stem was 98.3 %, and cumulative probability of radiographic survivorship was 87.7 %. The advantages of this stem include a technically simple implantation, reliable osteointegration and long-term stability even in high demanding patients.
Klíčová slova: primary total hip replacement, uncemented stem
Zveřejněno: 1. srpen 2009 Zobrazit citaci
Reference
- ALDINGER, P. R., THOMSEN, M., MAU, H., EWERBECK, V., BREUSCH, S. J.: Cementless Spotorno tapered titanium stems: Excellent 10-15-year survival in 141 young patients. Acta orthop. scand., 74: 253-8, 2003.
Přejít k původnímu zdroji...
- BLÄSIUS, K., COTTA, H., SCHNEIDER, U., THOMSEN, E.: CLS Multicenter-Studie. 8 Jahre Ehrfahrungen. Z. Orthop., 131: 477-616, 1993.
Přejít k původnímu zdroji...
Přejít na PubMed...
- BROOKER, A. F., BOWERMAN, J. W, ROBINSON, R. A., RILEY, L. H. Jr.: Ectopic ossification following total hip replacement. Incidence and a method of classification. J. Bone Jt Surg., 55-A: 1629-1632, 1973.
Přejít k původnímu zdroji...
- BÜLLOW, J. U., SCHELLER, G., ARNOLD, P., SYNATSCHKE, M., JANI, L.: Follow-up (6-9) years results of the uncemented CLS Spotorno stem. Arch. Orthop. Trauma Surg., 115: 190-194, 1996.
Přejít k původnímu zdroji...
Přejít na PubMed...
- ČECH, O., FASSBENDER, M., KIRSCHNER, P., ROZKYDAL, Z.: Předoperační plánování a operačně-technické řešení stability a vyrovnání délky končetin u totální náhrady kyčelního kloubu. Acta Chir. orthop. Traum. čech., 69: 362-368, 2002.
- ENGH, C. A., BOBYN, J. D., GLASSMANN, A. H.: Porous coated hip replacement. The factors governing bone ingrowth, stress shielding and clinical results. J. Bone Jt Surg., 69-B: 45-55, 1987.
Přejít k původnímu zdroji...
Přejít na PubMed...
- GALLO, J., MRÁZEK, F., PETŘEK, M.: Podíl imunogenetických faktorů na vzniku a rozvoji periprotetické osteolýzy. Acta Chir. orthop. Traum. čech., 74: 247-252, 2007.
Přejít k původnímu zdroji...
- GRAPPIOLO, G., BLAHA, J. D., GRUEN, T. A., BURASTERO, G., SPOTORNO, L.: Primary total hip arthroplasty using a gritblasted, press-fit femoral prosthesis. Long-term results with survivorship analysis. Hip International, 12: 55-73, 2002.
Přejít k původnímu zdroji...
Přejít na PubMed...
- GÜTHER, D., PAP, G., BAJERY, P., EGGLI, S.: Long-term results with the cementless CLS stem in hip replacement [Langzeitresultate des unzementierten CLS-schaftes in der Hüftendoprothetik]. Z. Orthop., 141: 309-315, 2003.
Přejít k původnímu zdroji...
Přejít na PubMed...
- HAGEL, A., HEIN, W., WOHLRAB, D.: Experience with the Mayo Conservative Hip System. Acta Chir. orthop. Traum. čech., 75: 288-292, 2008.
Přejít k původnímu zdroji...
- HARRIS, W. H.: Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J. Bone Jt Surg., 51-A: 51: 737-755, 1969.
Přejít k původnímu zdroji...
- JANÍČEK, P., JANÍČEK, P., FUIS, V., PINK, T.: Necementovaná totální endoprotéza kyčelního kloubu, keramiika-keramika. Acta Chir. orthop. Traum. čech., 73: 283-286, 2006.
Přejít k původnímu zdroji...
- KAPLAN, E. L., MEIER, P.: Nonparametric estimation from incomplete observation, Amer. Stat. Ass. J., 53: 457-481, 1958.
Přejít k původnímu zdroji...
- KOVANDA, M., HAVLÍČEK, V., HUDEC, J.: Předčasné aseptické uvolňování dříku CF 30. Acta Chir. orthop. Traum. čech., 74: 59-64, 2007.
Přejít k původnímu zdroji...
- LANDOR, I., VAVŘÍK, P., SOSNA, A., BEK, J.: Totální náhrada kyčelního kloubu Walter - dlouhodobé výsledky. Acta Chir. orthop. Traum. čech., 68: 281-288, 2001.
- LEE, J. M., LEE, C. W.: Comparison of hydroxyapatite- coated and non hydroxyapatite- coated noncemented total hip arthroplasty in same patient. J. Arthroplasty, 22: 1019-1023, 2007.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MERLE D'AUBIGNE, R., POSTEL, M.: Functional results of hip arthroplasty with acrylic prosthesis. J. Bone Jt Surg., 36-A: 451-475, 1954.
Přejít k původnímu zdroji...
- MIN, B. W., SONG, K. S., BAE, K. C., CHO, C. H., KANG, C. H., KIM, S. Y.: The effect of stem alignment on results of total hip arthroplasty with a cementless tapered- wedge femoral component. J. Arthroplasty, 23: 418-423, 2008.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MORSCHER, E. W.: Endoprosthetics. Berlin, Heidelberg, New York, Springer Verlag 1995, 271-286.
Přejít k původnímu zdroji...
- PAVELKA, T., LINHART, M., HOUČEK, P.: Aloplastika kyčelního kloubu po operačním řešení zlomenin acetabula. Acta Chir. orthop. Traum. čech., 73: 268-274, 2006.
Přejít k původnímu zdroji...
- RADCLIFFE, G. S., WILSON, J. I., ASHFORD, R. U., DE BOER, P. G.: Hip replacement in patiens younger than 65 years: Results of the CLS prosthesis. Hip international, 14: 133-141, 2003.
Přejít k původnímu zdroji...
- ROZKYDAL, Z., JANÍČEK, P., ŠMÍD, Z.: Total hip replacement with the CLS expansion shell and a structural femoral head autograft for patients with congenital hip disease. J. Bone Jt Surg., 87-A: 801-7, 2005.
Přejít k původnímu zdroji...
- ROZKYDAL, Z., JANÍČEK, P., HAVLÍČEK, V., DEDUCH, J.: Revision hip surgery using the CLS expansion shell. Hip international, 16: 260-267, 2006.
Přejít k původnímu zdroji...
- ROZKYDAL, Z., JANÍČEK, P., ŠMÍD, Z.: Strukturální kostní štěp a CLS jamka u postdysplastické artrózy kyčle. Acta Chir. orthop. Traum. čech., 67: 298-306, 2000.
- SARMIENTO, A., LATTA, L.L.: A surgical technique for the prevemtion of femoral lysis in cemented total hip arthroplasty. Acta Chir. orthop. Traum. čech., 76: 85-89, 2009.
Přejít k původnímu zdroji...
- SIEBOLD, R., SCHELLER, G., SCHREINER, U., JANI, L.: Long-term results with the cement-free Spotorno CLS shaft. Orthopäde, 30:317-327, 2001.
Přejít k původnímu zdroji...
Přejít na PubMed...
- SPOTORNO, L., SCHENK, R. K., DIETSCHI, C., ROMAGNOLI, S., MUMENTHALER, A.: Unsere Ehrfahrungen mit nichtzementierten Prothesen. Orthopäde, 16: 225-238, 1987.
- SPOTORNO, L., MORASSO, V., ROMAGNOLI, S., IVALDO, N., GRAPPIOLO,G., BIBIANI, E., BLAHA, D. J., GRUEN, T. A.: The CLS system- theoretical concept and results. Acta orthop. belg., 59: 144-148, 1993.
- SPOTORNO L, GRAPPIOLO G, MUMENTHALER A.: The CLS Stem. In: Morscher EW, ed. Endoprosthetics. Berlin, Heidelberg, New York, Springer-Verlag 1995, 271-296.
Přejít k původnímu zdroji...
- SPOTORNO, L.: The CLS system - a 16 years review. An emerging gold standard for uncemented hip replacement. Insert in Orthopaedics, 24:1-8, 2000.
- STEHLÍK, J., MUSIL, D., HELD, M., STÁREK, M.: Náhrada kyčelního kloubu MIS-AL technikou - roční výsledky. Acta Chir. orthop. Traum. čech., 75: 262-270, 2008.
Přejít k původnímu zdroji...
- STROM, H., NILSSON, O., MILBRINK, J., MALLMIN, H., LARSSON, S.: The effect of early weight bearing on migration pattern of the uncemented CLS stem in total hip arthroplasty. J. Arthroplasty, 22: 1122-1129, 2007.
Přejít k původnímu zdroji...
Přejít na PubMed...