Acta Chir Orthop Traumatol Cech. 2009; 76(6):462-472 | DOI: 10.55095/achot2009/086
Oválné implantáty v problematice revizí totálních náhrad kyčelního kloubuPůvodní práce
- I. Ortopedická klinika 1. LF UK a FN Motol, Praha
PURPOSE OF THE STUDY:
A prerequisite for the successful implantation of an acetabular component in a defective bone tissue is, in addition to providing sufficient primary fixation of the implant, reconstruction of the acetabular bone bed. To achieve this, one of the options involves the use of an oblong implant. Data published on this topic are sparse and therefore the aim of this study was to gain a deeper insight into this issue. In addition, we wanted to compare the results achieved with the oblong component with those obtained using its original model.
MATERIAL:
One group comprised 111 patients with 133 sides who underwent acetabular revision for aseptic loosening or extraction of an infected acetabular component with subsequent implantation of an oblong cup (Langs-Ovale Revisionspfanne [L.O.R.], Allopro, Switzerland). The average age of this group at the time of surgery was 62.2 (range, 31-83) years, and average follow-up was 9.7 (range, 0.6-13.9) years. The other group consisted of 134 patients with 152 sides who for the same indications as the L.O.R. group received a Walter Oval cup (Medin Orthopaedics, Czech Republic). The average age at the time of surgery was 64.6 (22-86) years, and average follow-up was 7.3 (range, 1.1-9.8) years. The proportion and nature of defects and underlying clinical diagnoses in the two groups were statistically comparable The patients requiring replacement or removal of the acetabular component were not included in clinical evaluation, but their data were used for survival analysis. The clinical evaluation included: in the L.O.R. group, 115 hip joints at an average follow-up of 10.8 (range, 4.5-13.9) years and, in the Walter Oval group, 144 hip joints at an average follow-up of 7.5 (range, 2.3-9.8) years. The data of patients who died during ;the study (L.O.R., 7 Walter Oval, 11) were included in the clinical evaluation as of the date of the final follow-up.
METHODS:
The results for each group were evaluated using the Kaplan-Meier survival analysis, with a simple survival curve and a "worst case" survival curve. The statistical difference between the curves was calculated by the Gehan-Wilcoxon test. Survival tables were constructed for 12 or 8 years. A comparison of the initial and the final Harris hip score (HHS) was made using the t-test. Radiographs were inspected for the signs of implant migration, the presence of translucent lines surrounding the implant and screws and screw breaks. The results were evaluated by the Chi-square and Fisher's exact tests, with the level of significance set at 0.05.
RESULTS:
In the I.O.R. group, 18 implants (13.5 %) were reimplanted or removed in the Walter Oval group it was eight cups (5.3 %). Aseptic loosening was the cause of reimplantation in 8.3 % and 3.9 % of the hips in the L.O.R. and Walter Oval groups, respectively. Deep infection required revision surgery in 5.3 % of the L.O.R hips, and in 1.3 % of the Walter Oval hips. The Walter Oval group showed a longer implant survival, but this was not confirmed by the "worst case" analysis. The final HHS markedly improved in comparison with the initial one in both groups. No radiographic difference between the groups was found.
DISCUSSION:
The comparison of our results with those of other methods used in the indications described here provides evidence in favour of oblong implants. The major advantage, as well as the condition of success, is the anchoring of an oblong cup in the patient's own load-bearing bone.
CONCLUSIONS:
Acetabular defects in the range of Paprosky types IIB to IIIA are indicated for the use of oblong implants in a basic position. The Arbond hydroxyapatite coating providing an osteoactive surface for the oblong cup described significantly improves the survival of this implant in comparison with the original model.
Klíčová slova: oblong cup, hydroxyapatite, cementless, THR
Zveřejněno: 1. prosinec 2009 Zobrazit citaci
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
Reference
- BERRY, D. J., MUELLER, M. E: Revision arthroplasty using an anti-protrusio cage for massive acetabular bone deficiency. J. Bone Jt Surg., 74-B: 711-715, 1992.
Přejít k původnímu zdroji...
Přejít na PubMed...
- BERRY, D., SUTHERLAND, C. J., TROUSDALE, R. T: Bilobed, oblong, off-the-shelf acetabular components in revision total hip arthroplasty. EFORT, Barcelona, Spain, April 1997.
- BOZIC, K. J., FREIBERG, A. A., HARRIS, W. H: The High hip center. Clin. Orthop., 420:101-105, 2004.
Přejít k původnímu zdroji...
Přejít na PubMed...
- BUTTARO, M. A., MORANDI, A., GARCIA RIVELLO, H., PICCALUGA. F: Histology of vancomycin-supplemented impacted bone allografts in revision total hip arthroplasty. J. Bone Jt Surg., 87-B:1684-7, 2005.
Přejít k původnímu zdroji...
Přejít na PubMed...
- BUTTARO, M. A., PUSSO, R., PICCALUGA, E: Vancomycin-supplemented impacted bone allografts in infected hip arthroplasty. Two-stage revision results. J. Bone Jt Surg., 87-B:314-9, 2005.
Přejít k původnímu zdroji...
Přejít na PubMed...
- CAMERON, H. U: Cavity-filling components: When round isn't right. Orthopedics, 24: 879-81, 2001.
Přejít k původnímu zdroji...
Přejít na PubMed...
- COONEY, W. P., BERRY, D. J., HOXIE, S. C., HANSSEN, A. D: Burch-Schneider cage for revision THA with massive acetabular bone loss: results and complications. AAOS annual meeting. Washington DC, USA, 23-27 February 2005.
- DEBOER, D. K., CHRISTIE, M. J: Reconstruction of the deficient acetabulum with an oblong-shaped prosthesis: three to six year results. SIROT, Amsterdam, Netherlands, August 1996.
- DELEE, J. G., CHARNLEY, J: Radiological Demarcation of Cemented Sockets in Total Hip Replacement. Clin. Orthop., 121: 101-111, 1976.
Přejít k původnímu zdroji...
- FOUSEK, J., INDRÁKOVÁ, P: Totální endoprotéza kyčelního kloubu u postdysplastické koxartrózy: Má typ jamky a její umístění vliv na životnost endoprotézy? Acta Chir. orthop. Traum. čech., 74: 47-, 2007.
Přejít k původnímu zdroji...
- GALLO, J., ROZKYDAL, Z., SKLENSKÝ, M: Rekonstrukce závažných acetabulárních defektů pomocí Burchova-Schneiderova prstence Acta Chir. orthop. Traum. čech., 73: 157-163, 2006.
Přejít k původnímu zdroji...
- GALLO, J., MRÁZEK, F., PETŘEK, M: Podíl imunogenetických faktorů na vzniku a rozvoji periprotetické osteolýzy. Acta Chir. orthop. Traum. čech., 74: 247-, 2007.
Přejít k původnímu zdroji...
- GILL, T., SLEDGE, J., MULLER, M: The management of severe acetabular bone loss using structural allograft and acetabular reinforcement devices. J. Arthroplasty, 15:1-7, 2000.
Přejít k původnímu zdroji...
Přejít na PubMed...
- GOTZE, C., SIPPEL, C., WENDT, G., STEINBECK, J: Limits in cementless hip revision total hip arthroplasty. Midterm experience with an oblong revision cup. Z. Orthop., 141:182-9, 2003.
- GUSTKE, K. A: Treatment of large acetabular defects with jumbo cups. Orthopedics, 26: 379-82, 2003.
Přejít k původnímu zdroji...
Přejít na PubMed...
- HARRIS, W. H: Traumatic Arthritis of the Hip after Dislocation and Acetabular Fractures. Treatment by Mold Arthroplasty. J. Bone Jt Surg., 51-A: 737-755, 1969.
Přejít k původnímu zdroji...
- CHEN, W. M., ENGH, C. A. J. R., HOPPER, R. H., MCAULEY, J. P: Acetabular revision with use of a bilobed component inserted without cement inserted without cement in patinets who have acetabular bone-stock deficiency. J. Bone Jt Surg., 82-A: 197-201, 2000.
Přejít k původnímu zdroji...
Přejít na PubMed...
- JOHNSTON, R. C., FITZGERALD, R. H., HARRIS, W. H., POSS, R., MULLER, M. E., SLEDGE, C. B: Clinical and radiographic evaluation of total hip replacement. A standard system of terminology for reporting results. J. Bone Jt Surg., 72-A: 161-168, 1990.
Přejít k původnímu zdroji...
- KELLEY, S: High hip center in revision arthroplasty. J. Arthroplasty, 9:503-510, 1994.
Přejít k původnímu zdroji...
Přejít na PubMed...
- KOSTER, G., WILLERT, H. G., KOHLER, H. P., DOPKENS, K: An oblong revision cup for large acetabular defects. J. Arthroplasty, 13: 559-69, 1998.
Přejít k původnímu zdroji...
Přejít na PubMed...
- KOVANDA, M., HAVLÍČEK, V., HUDEC, J: Předčasné aseptické uvolňování dříku CF- 30. Acta Chir. orthop. Traum. čech., 74: 59-, 2007.
Přejít k původnímu zdroji...
- LACHIEWICZ, P. F., McCASKILL, B., INGLIS, A., RANAWAT, C. S., ROSENSTEIN, B. D: Total hip arthroplasty in juvenile rheumatoid arthritis: Two to eleven-year results. J. Bone Jt Surg., 68-A: 502-508, 1986.
Přejít k původnímu zdroji...
- MASÁR, J.: 10-ročné skúsenosti s individuálnou TEP podľa Aldingera - zhodnotenie výsledkov. Acta Chir. orthop. Traum. čech., 74: 175-, 2007.
Přejít k původnímu zdroji...
- NUNN, D., FREEMAN, M. A., HILL, P. F., EVANS, S. J: The measurement of migration of the acetabular component of hip prostheses. J. Bone Jt Surg., 71-B: 629-631, 1989.
Přejít k původnímu zdroji...
Přejít na PubMed...
- PAGNANO, M. W., HANSSEN, A. D., LEWALLEN, D. G., SHAUGHENESSY, W. J: The effect of superior placement of the acetabular component on the rate of loosening after total hip arthroplasty. Long-term results in patients who have Crowe type-II congenital dysplasia of the hip. J. Bone Jt Surg., 78-A: 1004-14, 1996.
Přejít k původnímu zdroji...
Přejít na PubMed...
- PAPROSKY, W. G, PERONA, P. G., LAWRENCE, J. M.: Acetabular defect classification and surgical reconstruction in revision arthroplasty: a 6-year follow-up evaluation. J. Arthroplasty, 9:33-44, 1994.
Přejít k původnímu zdroji...
Přejít na PubMed...
- RUSSOTTI, G. M., HARRIS, W. H: Proximal placement of the acetabular component in total hip arthroplasty. A long-term follow-up study J. Bone Jt Surg., 73-A: 587-592, 1991.
Přejít k původnímu zdroji...
- WHALEY, A. L., BERRY, D. J., HARMSEN, W. S: Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J. Bone Jt Surg., 83-A :1352-1357, 2001.
Přejít k původnímu zdroji...
Přejít na PubMed...
- YODER, S. A., BRAND, R. A., PEDERSEN, D. R., O'GORMAN, T. W: Total hip acetabular komponent position affects component loosening rates. Clin. Orthop., 228: 79-87, 1988.
Přejít k původnímu zdroji...