Acta Chir Orthop Traumatol Cech. 2009; 76(6):509-512 | DOI: 10.55095/achot2009/093

Heterotopic Excessive Wear Granuloma Mistaken for an Aneurysm of the External Iliac ArteryCase report

F. VESELÝ1,*, K. NOVOTNÝ2, A. SOSNA1
1 I. Ortopedická klinika 1. LF UK a FN Motol, Praha
2 Kardiochirurgická klinika FN Motol, Praha

Reimplantation of a total hip arthroplasty (THA) with excessive heterotopic polyethylene granuloma is reported. An 84-year-old woman, who had undergone THA reimplantation on the right side 4.5 years previously, was indicated for revision surgery due to aseptic failure of the acetabular component. Pre-operative examination revealed a pulsating mass below the right inguinal ligament that raised the suspicion of a pseudoaneurysm of the external iliac artery. Because of this suspected late complication of the first revision arthroplasty, surgical exploration was indicated by the vascular surgeon prior the second reimplantation. A CT-scan showed a large mass attached to a preserved lumen of the external iliac artery, and this was diagnosed by the vascular surgeon as a pseudoaneurysm. However, no pseudoaneurysm was found by a vascular surgery procedure, and the large mass ventrally extending the external iliac artery appeared to be a large polyethylene granuloma well enveloped in a fibrous pseudocapsula. The granuloma was removed and the wound sutured. Twelve days later, revision total hip arthroplasty and acetabular reconstruction were successfully carried out

Keywords: revision total hip arthroplasty, vascular injury, false aneurysm, polyethylene granuloma

Published: December 1, 2009  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
VESELÝ F, NOVOTNÝ K, SOSNA A. Heterotopic Excessive Wear Granuloma Mistaken for an Aneurysm of the External Iliac Artery. Acta Chir Orthop Traumatol Cech. 2009;76(6):509-512. doi: 10.55095/achot2009/093. PubMed PMID: 20067700.
Download citation

References

  1. AKGÜL, C., HANSEN, L. G., JONUNG, T. J., THOMASSEN, N.: Ugeskr. Laeg., 65: 583-5, 2003.
  2. BACH, C. M., STEINGRUBER, I., WIMMER, C., OGON, M., FRISCHHUT, B: Arthroplasty. 15: 535-8, 2000. Go to original source... Go to PubMed...
  3. BECHET, F.R., HIMMER, O., MAIRY, Y., LOOTVOET, L.: Arterial false aneurysm after total hip arthroplasty. A case report. Rev. Chir. orthop., 90: 365-8, 2004. Go to original source... Go to PubMed...
  4. GALLO, J., MRÁZEK, F., PETREK, M: Podíl imunogenetických faktorů na vzniku a rozvoji periprotetické osteolýzy. Acta Chir. orthop. Traum. čech., 74: 247-52, 2007. Go to original source...
  5. GUTTLER, K., POKORNÝ, D., SOSNA, A: Průběh arteria circumflexa femoris medialis a využití jeho znalosti při totálních náhradách kyčelního kloubu. Acta Chir. orthop. Traum. čech., 74: 377-381, 2007. Go to original source...
  6. MAKAR, R. R., SALEM, A., McGEE, H., CAMPBELL, D., BATESON, P: Endovascular treatment of bleeding external iliac artery pseudo-aneurysm following control of haemorrhage with Sengstaken tube during revision total hip arthroplasty. Ann. R. Coll. Surg., 89: W4-7, 2007. Go to original source... Go to PubMed...
  7. MOLFETTA, L., CHIAPALE, D., CALDO, D., LEONARDI, F: Hip Int., 17: 234-6, 2007. Go to original source...
  8. NAKAMURA, Y., MITSUI, H., TOH, S., HAYASHI, Y: Femoral nerve palsy associated with iliacus hematoma following pseudoaneurysm after revision hip arthroplasty. J. Arthroplasty, 23: 1240.e1-4. Epub 2008 Mar 14. Go to original source... Go to PubMed...
  9. NOZAWA, M., IRIMOTO, M., MAEZAWA, K., HIROSE, T., SHITOTO, K., KUROSAWA, H: False aneurysm of the profunda femoris artery after total hip arthroplasty. J. Arthroplasty, 15:671-4, 2000. Go to original source... Go to PubMed...
  10. PETRUSKA, J., DURCANSKÝ, D., MAKAREVIC, A., KUBOVICOVÁ, E., PIVKO, J: Morphological-functional characteristic of periarticular tissue after total hip arthroplasty: histological, cytochemical and electron microcopy aspects. Acta Chir. orthop. Traum. čech., 75:375-81, 2008. Go to original source...
  11. POKORNÝ, D., SLOUF, M., HORÁK, Z., JAHODA, D., ENTLICHER, G., EKLOVÁ, S., SOSNA, A: Metodika sledování distribuce otěrových částic UHMWPE v okolních tkáních u TEP kyčelního kloubu. Acta Chir. orthop. Traum. čech., 73: 243-50, 2006. Go to original source...
  12. PROSCHEK, D., PROSCHEK, P., HOCHMUTH, K., BALZER, J. O., MACK, M. G., VOGL, T. J: False aneurysm of the left femoral artery and thrombosis of the left femoral vein after total hip arthroplasty. Arch. Orthop. Trauma Surg., 126:493-7, 2006. Go to original source... Go to PubMed...
  13. SOSNA, A., ČECH, O., KRBEC, M: Operační přístupy ke skeletu končetin, pánve a páteře. Praha, Triton 2005, 100-150.
  14. SOSNA, A., RADONSKÝ, T., POKORNÝ, D., VEIGL, D., HORÁK, Z., JAHODA, D: Polyethylenová choroba. Acta Chir. orthop. Traum. čech., 70: 6-16, 2003.
  15. ULMAR, B., ASCHOFF, A. J., OREND, K. H., PUHL, W., HUCH, K: Minimally invasive intervention for acute bleeding from a pseudoaneurysm after revision hip arthroplasty. Acta orthop. belg., 70: 361-4, 2004.