Acta Chir Orthop Traumatol Cech. 2011; 78(4):321-327 | DOI: 10.55095/achot2011/049
Operační léčba zlomenin proximálního humeruPůvodní práce
- 1 Katedra válečné chirurgie, Fakulta vojenského zdravotnictví Univerzity obrany, Hradec Králové
- 2 Chirurgická klinika, FN Hradec Králové
- 3 Oddělení urgentní medicíny, FN Hradec Králové
PURPOSE OF THE STUDY:
The aim of the study was to compare the medical aspects of alternative surgical methods for treatment of proximal humerus fractures in specific indications (two- and three- fragment fractures).
MATERIAL AND METHODS:
A prospective randomised study on surgical treatment of two- and three-fragment fractures of the proximal humerus was carried out at the Department of Surgery, University Hospital in Hradec Králové, from January 2006 till January 2010. The study comprised patients with proximal humerus fractures indicated for surgical treatment.
Study inclusion criteria were as follows: informed consent, AO fracture types A2, A3, B1 or C1, age between 18 and 80 years, and patient compliance. Exclusion criteria included open fracture, associated injury (AIS ≥ 2), open growth plates, or such state of the patient's health that would limit the extent of surgery.
Two groups were compared. One included patients treated by the Zifko method of minimally invasive osteosynthesis with intramedullary K-wire insertion (MIO group) and the other (ORIF group) consisted of patients undergoing open reduction with angle-stable osteosynthesis using a Philos plate (Synthes, Switzerland).
The patients were randomised to the groups by a computer programme which facilitates the maintenance of homogeneity of the groups compared. The procedure in each patient was based on the sealed-envelope method.
RESULTS:
The ORIF group comprised 28 patients. It took them an average of 27.2 weeks (9-72) to regain normal upper limb function. The final CM score was 86.6% (64-100%) as compared with the healthy limb. Excellent and good results were achieved in 89% of the patients; complications were recorded in 39% of them.
The MIO group included 27 patients. The fractures healed in all of them. Normal upper limb function was regained at an average of 21.4 weeks (13-36). The final CM score was 87.5% (52-100%) in comparison with the healthy limb. Excellent and good results were achieved in 89% and complications developed in 33% of the patients.
CONCLUSIONS:
The statistical evaluation of the results, using the unpaired t-test, did not show any significant differences either in functional outcomes or the number of complications between the two groups. The only significant difference was found in operative times (117 min and 72 min in ORIF and MIO groups, respectively). The difference in time needed to regain limb function (27 and 21 weeks) was at a marginal level of statistical significance. With both methods 89% of excellent and good results were achieved, and a similar number of patients had complications (11 and 9).
Klíčová slova: proximal humerus fracture, prospective randomised study, minimally invasive intramedullary osteosynthesis, ORIF-plate fixation
Zveřejněno: 1. srpen 2011 Zobrazit citaci
Reference
- BJÖRKENHEIM, J-M., PAJARINEN, J., SAVOLAINEN, V.: Internal fixation of proximal humeral fractures with a locking compression plate. Acta Orthop. Scand., 75: 741-745, 2004.
Přejít k původnímu zdroji...
Přejít na PubMed...
- BRUNNER, A., WELLER, K., THORMANN, S., JÖCKEL, JA., BABST, R.: Closed reduction and minimally invasive percutaneus fixation of proximal humerus fractures using the humerusblock. J. Orthop. Trauma, 24: 407-413, 2010.
Přejít k původnímu zdroji...
Přejít na PubMed...
- CONSTANT, C. R., MURLEY, A. H.: A clinical method of functional assesment of the shoulder. Clin. Orthop., 214: 160-164, 1980.
Přejít k původnímu zdroji...
- COURT BROWN, C. M., GARG, A., MCQEEN, M. M.: The epidemiology of proximal humeral fractures. Acta Orthop. Scand., 72: 365-371, 2001.
Přejít k původnímu zdroji...
Přejít na PubMed...
- GARDNER, M. J., WEIL, Y., BARKER, J. U., KELLY, B. T., HELFET, D. L., LORICH, D. G.: The importance of medial support in locked plating of proximal humerus fractures. J. Orthop. Trauma, 21: 185-191, 2007.
Přejít k původnímu zdroji...
Přejít na PubMed...
- HAGG, O., LUNDBERG, B.: Aspects of prognostic factors in comminuted and dislocated proximal humeral fractures. In: BATEMAN, JE., WELSH, RP.: Surgery of Shoulder. Philadelphia, BC Decker 1984.
- HERSOVICI, D. Jr, SAUNDERS, D. T., JOHNSON, M. P., SANDERS, R., DIPASQUALE, T.: Percutaneus fixation of proximal humeral fractures. Clin. Orthop. Relat. Res., 375: 97-104, 2000.
Přejít k původnímu zdroji...
Přejít na PubMed...
- CHARALAMBOUS, C. P., SIDIQQUE, I., VALLURIPALLI, K., KOVACEVIC, M., PANOSE, P., SRINIVASAN, M., MARYNISSEN, H.: Proximal humeral internal locking system (PHILOS) for treatment of proximal humeral fractures. Arch. Orthop., 127: 205-210, 2007.
Přejít k původnímu zdroji...
Přejít na PubMed...
- JUPITER, J. B., WYSS, H.: Stable fixation of osteoporotic fractures and nonunions in the upper limb-life before the "Locking Plate". Acta Chir. orthop. Traum. čech., 77: 361-364, 2010.
Přejít k původnímu zdroji...
- KANNUS, P., PALVANEN, M., NIEMI, S., PARKKARI, J., JARVINEN, M., VUORI, I.: Increasing number and incidence of osteoporotic fractures of the proximal humerus in elderly people. BMJ, 313: 1051-1052, 1996.
Přejít k původnímu zdroji...
Přejít na PubMed...
- KHODADADYAN-KLOSTERMANN, C., RASCHKE, M., FONTES, R., MELCHER, I., SOSSAN, A., BAGCHI, K., HAAS, N.: Treatment of complex proximal humeral fratures with minimally invasive fixation of the humeral head combined with flexible intramedullary wire fixation - introduction of a new concept. Langenbecks Arch. Surg., 387: 153-160, 2002.
Přejít k původnímu zdroji...
Přejít na PubMed...
- KOPP, L., EDELMANN, K., OBRUBA, P., PROCHÁZKA, B., BL©«ÁKOVÁ, K., D®UPA, V.: Mortality risk factors in the elderly with proximal femoral fracture treated surgically. Acta Chir. orthop. Traum. čech., 76: 41-46, 2009.
Přejít k původnímu zdroji...
- KŘIVOHLÁVEK, M., LUKÁ©, R., TALLER, S., ©RÁM, J.: Use of angle-stable implants for proximal humeral fractures: prospective study. Acta Chir. orthop. Traum. čech., 75: 212-220, 2008.
Přejít k původnímu zdroji...
- LEONARD, M., MOKOTEDI, L., ALAO, U., GLYNN, A., DOLAN, M., FLEMING, P.: The use of locking plates in proximal humeral fractures: Comparison of outcome by patients age and fractures pattern. J. Shoulder Surg., 3: 85-89, 2009.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MARTINEZ, A. A., CUENCA, J., HERRERA, A.: Philos plate fixation for proximal humeral fractures. J. Orthop. Trauma Surg., 17: 10-14, 2009.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MATZIOLIS, D., KAEAEB, M., PERKA, C., GREINER, S.: Surgical treatment of two-part fractures of the proximal humerus: Comparison of fixed-angle plate osteosyntehsis and Zifko nails. Injury, 41: 1041-1046, 2010.
Přejít k původnímu zdroji...
Přejít na PubMed...
- QIDWAI, S. A.: Treatment of proximal humeral fractures by intramedullary Kirchner wires. J. Trauma, 50: 1090-1095, 2001.
Přejít k původnímu zdroji...
Přejít na PubMed...
- RESCH, H., HUBNER, C., SCHWAIGER, R.: Minimally invasive reduction and osteosynthesis of articular fractures of the humeral head. Injury, 32: S25-S32, 2001.
Přejít k původnímu zdroji...
Přejít na PubMed...
- SIWACH, R., SINGH, R., ROHILLA, R. K., KADIAN, V. S., SANGWAN, S. S., DHANDA, M.: Internal fixation of proximal humeral fractures with locking proximal humeral plate (LPHP) in elderly patiens with osteoporosis, J. Orthopaed. Traumatol., 9: 149-153, 2008.
Přejít k původnímu zdroji...
Přejít na PubMed...
- STROHM, P. C., HELWIG, P., KONRAD, G., SÜDKAMP, N. P.: Locking plates in proximal humerus fractures, Acta Chir. orthop. Traum. čech., 74: 410-415, 2007.
Přejít k původnímu zdroji...
- SÜDKAMP, N. P., BAYER, J., HEPP, P., VOIGT, C., OESTERN, H., KAAB, M., LUO, C., PLECKO, M., WENDT, K., KOSTLER, W., KONRAD, G.: Open reduction and internal fixation of proximal humeral fractures with use of the locking proximal humerus plate. J. Bone Jt Surg., 91: 1320-1328, 2009.
Přejít k původnímu zdroji...
Přejít na PubMed...
- THALHAMMER, G., PLATZER, P., OBERLEITNER, G., FIALKA, CH., GREITBAUER, M., VECSEI, V.: Angular stable fixation of proximal humeral fractures. J. Trauma, 66: 204-210, 2009.
Přejít k původnímu zdroji...
Přejít na PubMed...
- THANASAS, C., KONTAKIS, G., ANGOULES, A., LIMB, D., GIANNOUDIS, P.: Treatment of proximal humerus fractures with locking plates: a systematic review. J. Shoulder Elbow Surg., 18: 837-844, 2009.
Přejít k původnímu zdroji...
Přejít na PubMed...