PURPOSE OF THE STUDY:
The aim of the study was to evaluate the clinical and radiographic results of total hip arthroplasty (THA) with the Metha short hip stem and their comparison with the outcomes of THA using a conventional cementless stem.

MATERIAL AND METHODS:
A total of 30 Metha stems and 30 standard Biocontact stems implanted in the period from 2007 to 2012 were evaluated.
The Metha patient group comprised 22 women and six men, with the mean age of 58.9±SD 8.7 years (43-75), mean height of 164.2±6.3 cm (156-178), mean body mass of 68.2±12 (48-91) and mean BMI of 25±3.9 (19-32). The Biocontact group included 19 women and 11 men, with the mean age of 63.6±10.8 years (45-77), mean height of 166.6±6.6 cm (152-175), mean body mass of 77.6±13.1 (46-104) and mean BMI of 27.6±4.3 (20-37).
The evaluation was based on plain X-ray findings and clinical status assessed using the Harris hip score and 10-point visual analogue scale (VAS) for pain before surgery and at final follow-up.

RESULTS:
In the Metha group the mean pre- and post-operative Harris hip scores were 41.7±9.9 (28-57) and 94.4±5.1 (82-100), respectively. In the Biocontact group the values were 41.5±11.9 (32-64) and 89.3±11.2 (57-100), respectively. The mean VAS for low back and thigh pain improved from the pre-operative value of 7.41±2.1 (4-9) to 0.56±1.0 (0-3) in the Metha group and from 7.29±2.2 (4-9) to 1.64±1.8 (0-5) in the Biocontact group.
The post-operative results in both rating systems were significantly better (p<0.05) in the Metha than the Biocontact group patients. All stems showed radiographic evidence of good osteointegration. Stem subsidence and calcar atrophy were recorded in one patient of the Metha group. In the Biocontact group stem subsidence was found in two patients and signs of stress shielding in 14 patients.

DISCUSSION:
Short hip stems have been introduced in THA implantation with the aim to restore physiological biomechanics as much as possible and to ensure good long-term functioning of the joint replacement as well as to save the proximal femoral bone tissue for potential THA re-implantation. Our results of short hip stem implantation presented in this study are compared with the results of relevant recently published literature.

CONCLUSIONS:
Short hip stems show adequate osteointegration without need for diaphyseal fixation and allow for more natural weight-bearing distribution in the proximal femur. The short- and mid-term clinical results are better than with the use of conventional cementless stems. They can be recommended as an optimal choice for use in younger patients with good bone quality who are expected to require THA re-implantation.

Klíčová slova: total hip arthroplasty, short hip stem, Metha, Biocontact

Zveřejněno: 1. únor 2014  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Lacko M, Filip V, Čellár R, Vaško G. Naše skúsenosti s krátkym femorálnym driekom Metha. Acta Chir Orthop Traumatol Cech. 2014;81(1):70-76. doi: 10.55095/achot2014/008. PubMed PMID: 24755060.
Stáhnout citaci

Reference

  1. Bourne, R. B., Rorabeck, CH., Ghazal, M. E.: Pain in the thigh following total hip replacement with porous coated anatomic prosthesis for osteoarthrosis: a five-year follow-up study. J. Bone Jt Surg., 76-A: 1464-1470, 1994. Přejít k původnímu zdroji... Přejít na PubMed...
  2. Briem, D., Schneider, M., Bogner, N., Botha, N., Gebauer, M., Gehrke, T., Schwantes, B.: Mid-term results of 155 patients treated with a collum femoris preserving (CFP) short stem prosthesis. Int. Orthop., 35: 655-660, 2011. Přejít k původnímu zdroji... Přejít na PubMed...
  3. BROOKER, A. E., BOWERMAN, J. W., ROBINSON, R. A., RILEY, L. H., Jr.: Ectopic ossification following total hip replacement. Incidence and a method of classification. J. Bone Jt Surg., 55-A: 1629-1632, 1973. Přejít k původnímu zdroji...
  4. Bücking, P. K., Feldmann, P. H., Wittenberg, R. H.: Metha modular short stem prosthesis. Orthop. Prax., 42: 474-478, 2006.
  5. Eingartner, C., Heigele, T., Volkmann, R., Weise, K.: Long-term results of an uncemented straight femoral shaft prosthesis. Hip Int.,16: 23-32, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  6. Engh, J. r., Claus, A. M., Hopper, R.: Long-term results using the anatomic medullary locking hip prosthesis. Clin. Orthop. Relat. Res., 393: 137-146, 2001. Přejít k původnímu zdroji... Přejít na PubMed...
  7. ENGH, C. A., MASSIN, P., SUTHERS, K. E.: Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin. Orthop. Relat. Res., 257: 107-128, 1990. Přejít k původnímu zdroji...
  8. Falez, F., Casella, F., Panegrossi, G., Favetti, F., Barresi, C.: Perspectives on metaphyseal conservative stems. J. Orthop.Traumatol., 9: 49-54, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  9. Floerkemeier, T., Tscheuschner, N., Calliess, T., Ezechieli, M., Floerkemeier, S., Budde, S., Windhagen, H., von Lewinski, G.: Cementless short stem hip arthroplasty METHA® as an encouraging option in adults with osteonecrosis of the femoral head. Arch. Orthop. Trauma Surg., 132: 1125-1131, 2012. Přejít k původnímu zdroji... Přejít na PubMed...
  10. GRUEN, T. A., McNEICE, G. M., AMSTUTZ, H. C.: "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin. Orthop. Relat. Res., 141: 17-27, 1979. Přejít k původnímu zdroji...
  11. Hagel, A., Hein, W., Wohlrab, D.: Experience with the Mayo conservative hip system. Acta Chir. orthop Traum. čech., 75: 288-292, 2008. Přejít k původnímu zdroji...
  12. HARRIS, W. H.: Traumatic arthritis of the hip after dislocation and acetabular fractures: Treatment by mold arthroplasty. An end result study using a new method of result evaluation. J. Bone Jt Surg., 51-A: 737-755, 1969. Přejít k původnímu zdroji...
  13. Jakubowitz, E., Seeger, J. B., Lee, C., HEISEL, C., KRETZER, J. P., Thomsen, M. N.: Do short-stemmed-prostheses induce periprosthetic fractures earlier than standard hip stems? A biomechanical ex-vivo study of two different stem designs. Arch. Orthop. Trauma Surg., 129: 849-855, 2009. Přejít k původnímu zdroji... Přejít na PubMed...
  14. JASTY, M., KRUSHELL, R., ZALENSKI, E., O'CONNOR, D., SEDLACEK, R., HARRIS, W.: The contribution of the nonporous distal stem to the stability of proximally porous-coated canine femoral components. In J. Arthroplasty, 8: 33-41, 1993. Přejít k původnímu zdroji... Přejít na PubMed...
  15. Kendoff, D. O., Citak, M., Egidy, C. C., O'Loughlin, P. F., Gehrke, T.: Eleven-year results of the anatomic coated CFP stem in primary total hip arthroplasty. J. Arthroplasty, 28: 1047-1051, 2013. Přejít k původnímu zdroji... Přejít na PubMed...
  16. Kim, Y. H., Choi, Y., Kim, J. S.: Comparison of bone mineral density changes around short, metaphyseal-fitting, and conventional cementless anatomical femoral components. J. Arthroplasty, 26: 931-940, 2011. Přejít k původnímu zdroji... Přejít na PubMed...
  17. Kim, Y. H., Kim, J. S., Joo, J. H., Park, J. W.: A prospective short-term outcome study of a short metaphyseal fiting total hip arthroplasty. J. Arthroplasty. 27: 88-94, 2012. Přejít k původnímu zdroji... Přejít na PubMed...
  18. Kim, Y. H., Oh, S. H., Kim, J. S.: Primary total hip arthroplasty with a second-generation cementless total hip prosthesis in patients younger than fifty years of age. J. Bone Jt Surg., 85-A: 109-114, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  19. Learmonth, I. D.: Conservative stems in total hip replacement. Hip Int., 19: 195-200, 2009. Přejít k původnímu zdroji... Přejít na PubMed...
  20. Lindahl, H.: Epidemiology of periprosthetic femur fracture around a total hip arthroplasty. Injury. 38: 651-654, 2007. Přejít k původnímu zdroji... Přejít na PubMed...
  21. Molli, R. G., Lombardi, A. V., Berend, K. R., adams, j. b., sneller, m. a.: A short tapered stem reduces intraoperative complications in primary total hip arthroplasty. Clin. Orthop. Relat. Res., 470: 450-461, 2012. Přejít k původnímu zdroji... Přejít na PubMed...
  22. Morrey, b. f., Adams, R. A., Kessler, M.: A conservative femoral replacement for total hip arthroplasty. A prospective study. J. Bone Jt Surg., 82-B: 952-958, 2000. Přejít k původnímu zdroji...
  23. Pipino, F., Keller, A.: Tissue-sparing surgery: 25 years' experience with femoral neck preserving hip arthroplasty. J. Orthop. Traumatol., 7: 36-41, 2006. Přejít k původnímu zdroji...
  24. Pipino, F., Molfetta, L., Grandizio, M.: Preservation of the femoral neck in hip arthroplasty: results of a 13- to 17-year followup.. Ital. J. Orthop. Traumatol., 1: 31-39, 2000. Přejít k původnímu zdroji...
  25. Price, D. D., McGrath, P. A., RAfii, A., Buckingham, B.: The validation of visual analogue scales as ratio scale measures for chronic and experimental pain. Pain, 17: 45-56, 1983. Přejít k původnímu zdroji... Přejít na PubMed...
  26. Rometsch, E., Bos, P. K., Koes, B. W.: Survival of short hip stems with a "modern", trochanter-sparing design - a systematic literature review. Hip Int., 22: 344-354, 2012. Přejít k původnímu zdroji... Přejít na PubMed...
  27. Santori, F. S., Manili, M., Fredella, N., Tonci Ottieri, M., Santori, N.: Ultra-short stems with proximal load transfer: clinical and radiographic results at five-year follow-up. Hip Int., 16: 31-39, 2006. Přejít k původnímu zdroji...
  28. ŠPIČKA, J., RADOVÁ, L., GALLO, J. : TEP kyčle Plasmacup-Bicontact: výsledky s minimálně 10letým sledováním. Acta Chir. orthop. Traum. čech., 79: 317-323, 2012. Přejít k původnímu zdroji...
  29. Westphal, F. M., Bishop, N., Honl, M., hille, e., puschel, k., morlock, m. m: Migration and cyclic motion of a new short-stemmed hip prosthesis-a biomechanical in vitro study. Clin. Biomech., 21: 834-840, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  30. WHITESIDE, L. A., WHITE, S. E., MCCARTHY, D.: Effect of neck resection on torsional stability of cementless total hip replacement. Am. J. Orthop., 10: 766-770, 1995.
  31. ZICAT, B., ENGH, C. A., GOKCEN, E.: Patterns of osteolysis around total hip components inserted with and without cement. J. Bone Jt Surg., 77-A: 432-439, 1995. Přejít k původnímu zdroji... Přejít na PubMed...