Acta Chir Orthop Traumatol Cech. 2014; 81(3):212-220 | DOI: 10.55095/achot2014/023
Osteosyntéza zlomeniny acetabula: nová metoda předoperační modelace Omega dlahyPůvodní práce
- 1 Traumatologicko-ortopedické centrum se spinální jednotkou Krajské nemocnice Liberec, a.s., Liberec
- 2 Radiodiagnostické oddělení Krajské nemocnice Liberec, a.s., Liberec
- 3 Ortopedicko-traumatologická klinika 3. LF UK a FNKV Praha
PURPOSE OF THE STUDY:
The aim of the study was to describe a novel Omega plate and the procedure for obtaining an accurate pelvic inlet view, the mode of pre-operative plate contouring, the surgical procedure used and the evaluation of results in the first 15 patients treated using this method.
MATERIAL AND METHODS:
In the period 2009-2011, a total of 232 patients underwent osteosynthesis for pelvic fractures. Out of them, 52 were treated by the modified Stoppa approach and 12 with the original Omega plate. Between July 2010 and January 2014, a novel 3.5-mm Omega plate was used in 12 men and 3 women. The average duration of follow-up was 8.5 months in 11 patients; four were shortly after surgery.
The multi-functional Omega plate is described in detail. An exact pelvic inlet projection, named the "computer tomography-defined (CTD) view", was based on pre-operative CT examination. It facilitates pre-operative contouring of the plate according to a mirror image of the uninjured half of the pelvis. The surgical procedure enables us to apply the contoured plate to the correct position; the plate completes reduction, restores normal pelvic anatomy and makes operative time shorter. The radiographic evaluation of post-operative results was done using the Matta classification and functional outcome was assessed by the Harris Hip Score.
RESULTS:
Surgery using the isolated Stoppa approach was carried out in 11 patients and a procedure combining the Stoppa approach with another method was used in four patients. All operations were successfully completed, during two of them the external iliac vein was injured and treated by vascular suturing. No other vascular or nerve injury occurred. One deep wound infection successfully healed was recorded.
The post-operative radiographic results were excellent or satisfactory in 12 and poor in three patients. At follow-ups of 6 to 12 months, no failure of fracture reduction or osteosynthesis was recorded in 11 patients. Neither avascular necrosis of the femoral head nor heterotopic ossification was found. One patient showed signs of post-injury arthritis at 6 months after surgery.
The functional result assessed by the Harris Hip Score was excellent in seven patients, good in two (one of them with gonarthrosis), satisfactory in one patient with contralateral total hip replacement and ipsilateral gonarthrosis, and poor in one patient with hemiparesis after a stroke.
DISCUSSION:
Shape and size variability in CTD pelvic inlet views do not allow us to create a unified anatomically correct implant. Contouring during the operative procedure may not be accurate enough and significantly prolongs the time of surgery. Therefore, a custom-made plate for each patient seems to be an optimal method. It has been demonstrated on a group of 50 patients that CTD images of the right and left halves of the pelvis are identical in 68% and very similar (variation in length up to 5 mm and in curvature up to 3 mm) in 18%. At present plate contouring according to a mirror image of the acetabulum, which will be obtained by 3D printing, is prepared.
CONCLUSIONS:
Pre-operative contouring of an Omega plate based on a post-injury CT scan of the uninjured half of the pelvis is over 80% accurate or almost accurate. The multi-functional 3.5-mm pelvic plate Omega allows us to stabilise complicated fractures of the superior ramus of the pubic bone, anterior acetabular column or quadrilateral plate as well as fractures above the linea arcuata or uncomplicated fractures of the posterior column. The stabilisation of all fragments of the anterior column and quadrilateral plate is very firm and the Omega plate is resistant to fragment redisplacement. Also, it is its advantage that it can remain in situ if total hip arthroplasty is required later.
Klíčová slova: acetabular fracture, CT-defined inlet projection, modified Stoppa approach, Omega plate, 3D printing
Zveřejněno: 1. červen 2014 Zobrazit citaci
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
Reference
- COLE, J. D., BOLHOFNER, B. R.: Acetabular fracture fixation via a modified Stoppa limited intrapelvic approach: description of operative technique and preliminary treatment results. Clin. Orthop., 305: 112-123, 1994.
Přejít k původnímu zdroji...
- GÄNSSLEN, A., FRINK, M., HILDEBRAND, F., KRETTEK, C.: Both column fractures of the acetabulum: epidemiology, operative management and long-term results. Acta Chir. orthop. Traum. čech., 79: 107-113, 2012.
Přejít k původnímu zdroji...
- GRIFFIN, D. B., BEAULÉ, P. E., MATTA, J. M.: Safety and efficacy of the extended iliofemoral approach in the treatment of complex fractures of the acetabulum. J. Bone Jt Surg., 87-B: 1391-1396, 2005.
Přejít k původnímu zdroji...
Přejít na PubMed...
- D®UPA, V., TALLER, S.: Léčba zlomenin acetabula u pacientů s osteoporózou. In: D®UPA, V., PAVELKA, T., TALLER, S. (eds): Léčení zlomenin pánve a acetabula. Praha, Galén, 2013, 233-238.
- HARRIS, W. H.: Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J. Bone Jt Surg., 51-A: 737-755, 1969.
Přejít k původnímu zdroji...
- HIRVENSALO, E., LINDAHL, J., BOSTMAN, O.: A new approach to the internal fixation of unstable pelvic fractures. Clin. Orthop., 297: 28-32, 1993.
Přejít k původnímu zdroji...
- KACRA, B. K., ARAZI, M., CICEKCIBASI, A. E., BUYUKMUMCU, M., DEMIRCI, S.: Modified medial Stoppa approach for acetabular fractures: an anatomic study. J. Trauma, 71: 1340-1344, 2011.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MAST, J., JAKOB, R., GANZ, R.: Planning and reduction technique in fracture surgery. New York: Springer-Verlag, 1989.
Přejít k původnímu zdroji...
- MATTA, J. M.: Fractures of the acetabulum: accuracy of reduction and clinical results in patients managed operatively within three weeks after injury. J. Bone Jt Surg., 78-A: 1632-1645, 1996.
Přejít k původnímu zdroji...
- MATTA, J. M.: Operative treatment of acetabular fractures through the ilioinguinal approach: a 10 -year perspective. J. Orthop. Trauma, 20: S20-S29, 2006.
Přejít k původnímu zdroji...
Přejít na PubMed...
- MENG XU, LI-HAI ZHANG, YING-ZE ZHANG, CHUN-QING HE, LI-CHENG ZHANG, YAN WANG, PEI-FU TANG: Development of site-specific locking plates for acetabular fractures. Orthopedics, 36: e593-600, 2013.
Přejít k původnímu zdroji...
Přejít na PubMed...
- PAVELKA, T., HOUČEK, P.: Komplikace operačního léčení zlomenin acetabula. Acta Chir. orthop. Traum. čech., 76: 186-193, 2009.
Přejít k původnímu zdroji...
- SAGI, H. C., AFSARI, A., DZIADOSZ, D.: The anterior intra-pelvic (modified rives-stoppa) approach for fixation of acetabular fractures. J. Orthop.Trauma, 24: 263-270, 2010.
Přejít k původnímu zdroji...
Přejít na PubMed...
- SCHÄFFLER, A., DÖBELE, S., MAUCHER, M., STUBY, F., STÖCKLE, U., KÖNIG, B.: Biomechanische Testung und erste klinische Erfahrungen einer neuen Azetabulumflügelplatte. In: DKOU 2013, Deutcher Kongress für Ortopädie und Unfallchirurgie. Berlin: October 22-25, 2013.
- STOPPA, R. E., RIVES, J. L., WARLAUMONT, C. R., PALOT, J. P., VERHAEGHE, P. J., DELATTRE, J. F.: The use of Dacron in the repair of hernias of the groin. Surg. Clin. North. Am., 64: 269-285, 1984.
Přejít k původnímu zdroji...
Přejít na PubMed...
- ©RÁM, J.: New plate for reconstruction quadrilateral surface of the acetabulum. In: ECTES 2012. 13th European Congress of Trauma & Emergency Surgery. Many ways-one goal. Basel, May 12-15, 2012.
- ©RÁM, J., TALLER, S., LUKÁ©, R.: Uľití Omega dlahy při stabilizaci zlomenin acetabula - první zkuąenosti. Acta Chir. orthop. Traum. čech., 80: 118-124, 2013.
Přejít k původnímu zdroji...
- TALLER, S., ©RÁM, J., LUKÁ©, R., KŘIVOHLÁVEK, M.: Zlomeniny pánevního kruhu a acetabula operované přístupem podle Stoppy. Acta Chir. orthop. Traum. čech., 77: 93-98, 2010.
Přejít k původnímu zdroji...