Acta Chir Orthop Traumatol Cech. 2020; 87(5):350-355 | DOI: 10.55095/achot2020/053

Comparison of Clinical and Radiological Results of Two Fixation Materials after Distal Chevron Osteotomy for Hallux Valgus? - Two Kirschner Wires versus Single Screw FixationOriginal papers

E. BİLGİN1, T. KEÇECİ2, A. TURGUT1, L. ADIYEKE3, B. E. KİLİNC4,*
1 Health Science University Tepecik Training and Research Hospital, Department of Orthopaedics and Traumatology Izmir, Turkey
2 Şebinkarahisar State Hospital, Department of Orthopaedics and Traumatology, Giresun, Turkey
3 Health Science University Haydarpaşa Numune Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey
4 Health Science University Fatih Sultan Mehmet Training and Research Hospital, Department of Orthopaedics and Traumatology, Istanbul, Turkey

PURPOSE OF THE STUDY:
Although distal chevron osteotomy (DCO) is considered as an intrinsically stable osteotomy, various fixation methods have been used to date. The purpose of this study was comparison of two commonly used methods in DCO, Kirschner (K)-wire and titanium fully threaded headless cannulated screw fixation, based on the clinical and radiological results, and their complications.

MATERIAL AND METHODS:
Thirty patients were included in K-wire group and 36 patients were included in screw group. Mean age was 43.4 11.1 (rage; 19-65) years, and mean follow-up was 21.2 5.5 (range; 12-35) months. American Orthopaedic Foot Ankle Society (AOFAS) metatarsophalengeal-interphalangeal score was used for clinical evaluation. For radiological evaluation, hallux valgus angle (HVA), first-second intermetatarsal angle (IMA), distal metatarsal articular angle (DMAA), medial sesamoid grade (MSG), and lateral sesamoid distance (LSD) to mid-axis of the second metatarsal were measured for all patients on both preoperative and postoperative final follow-up radiographs.

RESULTS:
Mean AOFAS scores were significantly improved and radiographic measurements were significantly reduced at postoperatively in both groups (p < 0.01 for AOFAS, HVA, IMA, DMAA and MSG; p = 0.01 for LSD). Mean preoperative and mean postoperative, as well as the mean difference (difference between postoperative and preoperative) of the radiographic measurements, and AOFAS scores were not significantly different between two groups (p > 0.05). A total of 5 complications were observed (four in K-wire group, one in screw group). Complication rates between two groups was not statistically significant (p = 0.12).

DISCUSSION:
Initial description of DCO did not include any fixation material. Afterwards, the procedure was modified by using single K wire in order to enhance the stability of the osteotomy. Previous studies were unable to demonstrate significant differences between K-wire fixation and cortical or Herbert type screw fixation based on clinical and radiological outcomes. Differently, in this study we compared two K-wire fixation with 3.5-mm titanium fully threaded headless cannulated screw fixation. Our results demonstrated that function and radiological measurements significantly improved after both fixation methods. Despite the increased complication rate in K-wire group, it was not statistically significant. Moreover, none of the complications was associated with unstable osteotomy, and required re-operation.

CONCLUSIONS:
Both fixation methods provided comparable radiological and clinical outcomes with favourable results after DCO.

Keywords: hallux valgus, distal chevron osteotomy, Kirschner wire, headless cannulated screw, fixation method

Published: October 1, 2020  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
BİLGİN E, KEÇECİ T, TURGUT A, ADIYEKE L, KİLİNC BE. Comparison of Clinical and Radiological Results of Two Fixation Materials after Distal Chevron Osteotomy for Hallux Valgus? - Two Kirschner Wires versus Single Screw Fixation. Acta Chir Orthop Traumatol Cech. 2020;87(5):350-355. doi: 10.55095/achot2020/053. PubMed PMID: 33146604.
Download citation

References

  1. Andrews BJ, Fallat LM, Kish JP. Screw versus plate fixation for chevron osteotomy: a retrospective study. J Foot Ankle Surg. 2016;55:81-84. Go to original source... Go to PubMed...
  2. Armstrong DG, Pupp GR, Harkless LB. Our fixation with fixation: are screws clinically superior to external wires in distal first metatarsal osteotomies? J Foot Ankle Surg.1997;36:353-355. Go to original source... Go to PubMed...
  3. Austin DW, Leventen EO. A new osteotomy for hallux valgus: a horizontally directed" V" displacement osteotomy of the metatarsal head for hallux valgus and primus varus. Clin Orthop Relat Res. 1981;157:25-30. Go to original source...
  4. Ben-Ad R. Fixation updates for hallux valgus correction. Clin Podiatr Med Surg. 2014;31:265-279. Go to original source... Go to PubMed...
  5. Choi YR, Lee SJ, Kim JH, Kim TH, Oh CH. Effect of metatarsal osteotomy and open lateral soft tissue procedure on sesamoid position: radiological assessment. J Orthop Surg Res. 2018;13:11. Go to original source... Go to PubMed...
  6. Choi YR, Lee HS, Jeong JJ, Kim SW, Jeon IH, Lee DH, Lee WC. Hallux valgus correction using transarticular lateral release with distal chevron osteotomy. Foot Ankle Int. 2012;33:838-843. Go to original source... Go to PubMed...
  7. Chuckpaiwong B. Comparing proximal and distal metatarsal osteotomy for moderate to severe hallux valgus. Int Orthop. 2012;36:2275-2278. Go to original source... Go to PubMed...
  8. Coughlin MJ, Jones CP. Hallux valgus: demographics, etiology, and radiographic assessment. Foot Ankle Int. 2007;28:759-777. Go to original source... Go to PubMed...
  9. Crosby LA, Bozarth GR. Fixation comparison for chevron osteotomies. Foot Ankle Int. 1998;19:41-43. Go to original source... Go to PubMed...
  10. Dalton SK, Bauer GR, Lamm BM, Hillstrom HJ, Spadone SJ. Stability of the offset V osteotomy: effects of fixation, orientation, and surgical translocation in polyurethane foam models and preserved cadaveric specimens. J Foot Ankle Surg. 2003;42:53-62. Go to original source... Go to PubMed...
  11. Goforth WP, Martin JE, Domrose DS, Sligh TS. Austin bunionectomy using single screw fixation: five-year versus 18-month follow-up findings. J Foot Ankle Surg. 1996;35:255-259. Go to original source... Go to PubMed...
  12. Hanft JR, Kashuk KB, Bonner AC, Toney M, Schabler J. Rigid internal fixation of the Austin/Chevron osteotomy with Herbert screw fixation: a retrospective study. J Foot Surg. 1992;31:512-518. Go to PubMed...
  13. Kilinc BE, Oc Y, Erturer RE. Modified Lindgren-Turan osteotomy for hallux valgus deformity - a review of 60 cases. Acta Chir Orthop Traumatol Cech. 2018;85:325-330. Go to original source... Go to PubMed...
  14. Komur B, Yilmaz B, Kaan E, Yucel B, Duymus TM, Ozdemir G, Guler O. Mid-term results of two different fixation methods for Chevron osteotomy for correction of hallux valgus. J Foot Ankle Surg. 2018;57: 904-909. Go to original source... Go to PubMed...
  15. Knecht JG, VanPelt WL. Austin bunionectomy with Kirschner wire fixation. J Am Podiatr Med Assoc. 1981;71:139-144. Go to original source... Go to PubMed...
  16. Park YB, Lee KB, Kim SK, Seon JK, Lee JY. Comparison of distal soft-tissue procedures combined with a distal chevron osteotomy for moderate to severe hallux valgus: first web-space versus transarticular approach. J Bone Joint Surg Am. 2013;95: e158. Go to original source... Go to PubMed...
  17. Sammarco VJ, Acevedo J. Stability and fixation techniques in first metatarsal osteotomies. Foot Ankle Clin. 2001;6:409-432. Go to original source... Go to PubMed...
  18. Schneider W, Csepan R, Knahr K. Reproducibility of the radiographic metatarsophalangeal angle in hallux surgery. J Bone Joint Surg Am. 2003;85:494-499. Go to original source... Go to PubMed...
  19. Shereff MJ, Sobel MA, Kummer FJ. The stability of fixation of first metatarsal osteotomies. Foot Ankle. 1991;11:208-211. Go to original source... Go to PubMed...
  20. Smith RW, Reynolds JC, Stewart MJ. Hallux valgus assessment: report of research committee of American Orthopaedic Foot and Ankle Society. Foot Ankle. 1984;5:92-103.
  21. Trost M, Bredow J, Boese CK, Loweg L, Schulte TL, Scaal M, Oppermann J. Biomechanical comparison of fixation with a single screw versus two Kirschner wires in distal chevron osteotomies of the first metatarsal: a cadaver study. J Foot Ankle Surg. 2018;57:95-99. Go to original source... Go to PubMed...
  22. Viehe R, Haupt DJ, Heaslet MW, Walston S. Complications of screw-fixated chevron osteotomies for the correction of hallux abducto valgus. J Am Podiatr Med Assoc. 2003;93:499-502. Go to original source... Go to PubMed...
  23. Winemaker MJ, Amendola A. Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron osteotomies for hallux valgus. Foot Ankle Int. 1996;17: 623-628. Go to original source... Go to PubMed...
  24. Zelen CM, Young NJ. Alternative methods in fixation for capital osteotomies in hallux valgus surgery. Clin Podiatr Med Surg. 2013;30:295-306. Go to original source... Go to PubMed...