Acta Chir Orthop Traumatol Cech. 2011; 78(3):208-214 | DOI: 10.55095/achot2011/033
Cerclage Handling for Improved Fracture Treatment. A Biomechanical Study on the Twisting ProcedureOriginal papers
- 1 AO Research Institute Davos, Davos, Switzerland
- 2 AO Foundation Davos, Davos, Switzerland
- 3 Institute for Health and Biomedical Innovation (IHBI), Queensland University of Technology, Queensland, Australia
PURPOSE OF THE STUDY:
Twisting is clinically the most frequently applied method for tightening and maintaining cerclage fixation. The twisting procedure is controversially discussed. Several factors during twisting affect the mechanical behaviour of the cerclage. This in vitro study investigated the influence of different parameters of the twisting procedure on the fixation strength of the cerclage in an experimental setup with centripetal force application.
MATERIAL AND METHODS:
Cortical half shells of the femoral shaft were mounted on a testing fixture. 1.0 mm, 1.25 mm and 1.5 mm stainless steel wire cerclages as well as a 1.0mm cable cerclage were applied to the bone. Pretension of the cerclage during the installation was measured during the locking procedure. Subsequently, cyclic testing was performed up to failure.
RESULTS:
Higher pretension could be achieved with increasing wire diameter. However, with larger wire diameter the drop of pretension due to the bending and cutting the twist also increased. The cable cerclage showed the highest pretension after locking. Cerclages twisted under traction revealed significantly higher initial cerclage tension. Plastically deformed twists offered higher cerclage pretension compared to twists which were deformed in the elastic region of the material. Cutting the wire within the twist caused the highest loss of cerclage tension (44% initial tension) whereas only 11 % was lost when cutting the wire ends separately. The bending direction of the twist significantly influenced the cerclage pretension. 45% pretension was lost in forward bending of the twist, 53% in perpendicular bending and 90% in backward bending.
CONLUSION
Several parameters affect the quality of a cerclage fixation. Adequate installation of cerclage wires could markedly improve the clinical outcome of cerclage.
Keywords: biomechanics, cerclage wire, cerclage cable, cerclage, periprosthetic fractures
Published: June 1, 2011 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- BARTONICEK, J., LUNACEK, L., FRIC, V.: S-ROM Modular THR System - Three and Half Years of Experience. Acta Chir. orthop. Traum. čech., 67(6): 372-381, 2000.
- BIDDAU, F., FIORITI, M., BENELLI, G.: Migration of a broken cerclage wire from the patella into the heart. A case report. J. Bone Jt Surg. Amer., 88(9): 2057-2059, 2006.
Go to original source...
Go to PubMed...
- BLASS, C. E., PIERMATTEI, D. L., WITHROW, S. J., SCOTT, R. J.: Static and Dynamic Cerclage Wire Analysis. Vet. Surg., 15(2): 181-184, 1986.
Go to original source...
- BOSTROM, M. P., ASNIS, S. E., ERNBERG, J. J., WRIGHT, T. M., GIDDINGS, V. L., BERBERIAN, W. S., MISSRI, A. A.: Fatigue testing of cerclage stainless steel wire fixation. J. Orthop. Trauma, 8(5): 422-428, 1994.
Go to original source...
Go to PubMed...
- CARLS, J., KOHN, D., ROSSIG, S.: A comparative study of two cerclage systems. Arch. Orthop. Trauma Surg., 119(1-2): 67-72, 1999.
Go to original source...
Go to PubMed...
- CHENG, S. L., SMITH, T. J., DAVEY, J. R.: A comparison of the strength and stability of six techniques of cerclage wire fixation for fractures. J. Orthop. Trauma, 7(3): 221-225, 1993.
Go to original source...
Go to PubMed...
- DALL, D. M..MILES, A. W.: Re-attachment of the greater trochanter. The use of the trochanter cable-grip system. J. Bone Jt Surg. 65-B: 55-59, 1983.
Go to original source...
Go to PubMed...
- DENNIS, M. G., SIMON, J. A., KUMMER, F. J., KOVAL, K. J., DI CESARE, P. E.: Fixation of periprosthetic femoral shaft fractures: a biomechanical comparison of two techniques. J. Orthop. Trauma, 15(3): 177-180, 2001.
Go to original source...
Go to PubMed...
- DENNIS, M. G., SIMON, J. A., KUMMER, F. J., KOVAL, K. J., DICESARE, P. E.: Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem: a biomechanical study of 5 techniques. J. Arthropl., 15(4): 523-528, 2000.
Go to original source...
Go to PubMed...
- GUADAGNI, J. R..DRUMMOND, D. S.: Strength of surgical wire fixation. A laboratory study. Clin. Orthop. Relat. Res., (209): 176-181, 1986.
Go to original source...
- HARNROONGROJ, T.: Twist knot cerclage wire: the appropriate wire tension for knot construction and fracture stability. Clin. Biomech. (Bristol., Avon.), 13(6): 449-451, 1998.
Go to original source...
Go to PubMed...
- INCAVO, S. J., DIFAZIO, F., WILDER, D.: Strength of cerclage fixation systems: a biomechanical study. Clin. Biomech., 5(4): 236-238, 1990.
Go to original source...
Go to PubMed...
- KANAKIS, T. E., CORDEY, J.: Is there a mechanical difference between lag screws and double cerclage? Injury, 22(3): 185-189, 1991.
Go to original source...
Go to PubMed...
- KRBEC, M., MOTYCKA, J., LUNACEK, L., DOUSA, P.: Osteosynthesis for periprosthetic supracondylar fracture above a total knee arthroplasty using a locking compression plate. Acta Chir. orthop. Traum. čech., 76(6): 473-478, 2009.
Go to original source...
- LIU, A., O'CONNOR, D. O., HARRIS, W. H.: Comparison of cerclage techniques using a hose clamp versus monofilament cerclage wire or cable. J. Arthropl., 12(7): 772-776, 1997.
Go to original source...
Go to PubMed...
- MAKKI, D. Y., GORU, P., PRAKASH, V., ALDAM, C. H.: Migration of a Broken Trochanteric Wire to the Popliteal Fossa. J. Arthropl., 2010.
- MEHTA, V., FINN, H. A.: Femoral artery and vein injury after cerclage wiring of the femur: a case report. J. Arthropl., 20(6): 811-814, 2005.
Go to original source...
Go to PubMed...
- MEYER, D. C., RAMSEIER, L. E., LAJTAI, G., NOTZLI, H.: A new method for cerclage wire fixation to maximal pre-tension with minimal elongation to failure. Clin. Biomech. (Bristol., Avon.), 18(10): 975-980, 2003.
Go to original source...
Go to PubMed...
- MUNOZ-MAHAMUD, E., BORI, G., CUNE, J., FONT, L., DOMINGO, A., SUSO, S.: Results of treatment of subtrochanteric femoral fractures with the AO/ASIF Long Trochanteric Fixation Nail (LTFN). Acta Chir. orthop. Traum. čech., 76(6): 451-455, 2009.
Go to original source...
- NYROP, K. A., DEBOWES, R. M., FERGUSON, H. R., LEIPOLD, H. W., WILSON, J. W., GUFFY, M. M.: Vascular response of the equine radius to cerclage devices. Vet. Surg., 19(4): 249-253, 1990.
Go to original source...
Go to PubMed...
- OH, I., SANDER, T. W., TREHARNE, R. W.: The fatigue resistance of orthopaedic wire. Clin. Orthop. Relat. Res., (192): 228-236, 1985.
Go to original source...
- OLD, A. B., McGRORY, B. J., WHITE, R. R., BABIKIAN, G. M.: Fixation of Vancouver B1 peri-prosthetic fractures by broad metal plates without the application of strut allografts. J. Bone Jt Surg. Br., 88(11): 1425-1429, 2006.
Go to original source...
Go to PubMed...
- PERREN, S. M., FERNANDEZ DELL'OCA, A., LENZ, M., WINDOLF, M.: Cerclage, evolution and potential of a cinderella technology. An overview with reference to periprosthetic fractures. Acta Chir. orthop. Traum. čech., 78 (3): 190-199, 2011.
Go to original source...
- RHINELANDER, F. W., STEWART, C. L.: Experimental fixation of femoral osteotomies by cerclage with nylon straps. Clin. Orthop. Relat. Res., (179): 298-307, 1983.
Go to original source...
- RITTER, M. A., LUTGRING, J. D., DAVIS, K. E., BEREND, M. E., MEDING, J. B.: A clinical, radiographic, and cost comparison of cerclage techniques: wires vs cables. J. Arthropl., 21(7): 1064-1067, 2006.
Go to original source...
Go to PubMed...
- ROOKS, R. L., TARVIN, G. B., PIJANOWSKI, G. J., DALY, W. B.: In Vitro Cerclage Wiring Analysis. Vet. Surg., 11(2): 39-43, 1982.
Go to original source...
- SCHULTZ, R. S., BOGER, J. W., DUNN, H. K.: Strength of stainless steel surgical wire in various fixation modes. Clin. Orthop. Relat. Res., (198): 304-307, 1985.
Go to original source...
- SHAW, J. A., DAUBERT, H. B.: Compression capability of cerclage fixation systems. A biomechanical study. Orthopedics, 11(8): 1169-1174, 1988.
Go to original source...
Go to PubMed...
- STEINBERG, E. L., SHAVIT, R.: Braided cerclage wires: A biomechanical study. Injury, 2010.
Go to original source...
- TOMAS, T., NACHTNEBL, L., OTIEPKA, P.: Distal femoral periprosthetic fractures: classification and therapy. Acta Chir. orthop. Traum. čech., 77(3): 194-202, 2010.
Go to original source...
- VOIGT, C., HURSCHLER, C., RECHI, L., VOSSHENRICH, R., LILL, H.: Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates: no effect on fracture stabilization and rotator cuff function in human shoulder specimens. Acta Orthop., 80(4): 465-471, 2009.
Go to original source...
Go to PubMed...
- VON ISSENDORFF, W. D., AHLERS, J., RITTER, G.: [Tension band wiring osteosynthesis-studies on tension and fixation of the osteosynthesis wire]. Unfallchirurgie, 16(6): 277-285, 1990.
Go to original source...
Go to PubMed...
- WILSON, J. W.: Knot strength of cerclage bands and wires. Acta Orthop. Scand., 59(5): 545-547, 1988.
Go to original source...
Go to PubMed...
- WILSON, J. W., RHINELANDER, F. W., STEWART, C. L.: Microvascular and histologic effect of circumferential wire on appositional bone growth in immature dogs. J. Orthop. Res., 3(4): 412-417, 1985.
Go to original source...
Go to PubMed...