Acta Chir Orthop Traumatol Cech. 2020; 87(2):114-119 | DOI: 10.55095/achot2020/018
Treatment of Fractures of the Distal Third of Tibia Diaphysis by MIPO TechniqueOriginal papers
- Ortopedická klinika 1. lékařské fakulty Univerzity Karlovy, IPVZ a Nemocnice Na Bulovce, Praha
PURPOSE OF THE STUDY:
MIPO (Minimally Invasive Plate Osteosynthesis) technique is currently a commonly used method to treat fractures of the distal third of tibia diaphysis. At the same time, it is just like other methods accompanied by a relatively high complication rate. The purpose of this study was to determine whether the use of this technique at our department is effective and whether the complication rate does not differ considerably from values reported by literature.
MATERIAL AND METHODS:
In the period 2014-2016, minimally invasive plate osteosynthesis was performed in a total of 42 patients, who had suffered a fracture of the distal third of tibia diaphysis. They sustained a low-energy trauma. The mean age of patients was 50 years (range 27-86 years) and the mean follow-up period was 11.8 months (range 1.5-38 months). All the patients were treated with a minimally invasive technique with the use of subcutaneous LCP. In 41 patients (98%) it was inserted via anteromedial approach. In one patient only (2%), the LCP was inserted via anterolateral approach due to the unfavourable local finding on the medial side of the distal lower limb.
RESULTS:
Of the total number of operated patients, 35 patients (83%) underwent surgery within 24 hours of injury, including two patients in whom an external fixator was used. The mean operative time was 61 minutes (range of 30-150 minutes). The primary healing occurred in 93% of patients with radiological signs of healing within 5.6 months on average (range of 1.5-16 months). Time to full weight bearing was 4.2 months on average (range of 1.5-16 months). Delayed healing was observed in four patients. In three patients, a non-union developed, necessitating revision surgery. Infectious complications were reported in seven patients, in three of whom deep wound infection developed. In one case, the chronic infection resulted in a lower limb amputation. In five patients mal-union occurred.
DISCUSSION:
The outcomes achieved by the authors in treating fractures of the distal third of tibia diaphysis with a minimally invasive technique do not considerably differ from the outcomes reported by other authors in literature. In terms of the outcomes and the complication rate, the MIPO method is comparable to the treatment of these fractures with the use of nails. Limiting for fracture healing is the vascular supply. Therefore, in treating these injuries it is necessary to proceed with minimum invasiveness and carefulness and to seek to limit any additional trauma to soft tissues, thus also to vascular supply. In case of syndesmosis failure, the concurrent treatment of distal fibula fractures is clearly indicated. In case of intact syndesmosis, fibular osteosynthesis and the sequence of procedures are to be decided by the surgeon. At present, rigid osteosynthesis is being abandoned for potential slower healing up to development of non-unions.
CONCLUSIONS:
The treatment of fractures of the distal third of tibia diaphysis remains an unsolved issue despite the development of state-of-the art materials, implants and surgical techniques. The MIPO technique can be considered an effective method of treatment of these types of fractures, achieving a high success rate of healing and acceptable rate of complications.
Keywords: minimally invasive plate osteosynthesis (MIPO), distal third of tibia diaphysis, locking compression plate (LCP)
Published: April 1, 2020 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- Aksekili MA, Celik I, Arslan AK, Kalkan T, Uğurlu M. The results of minimally invasive percutaneous plate osteosynthesis (MIPPO) in distal and diaphyseal tibial fractures. Acta Orthop Traumatol Turc. 2012; 46:161-167.
Go to original source...
Go to PubMed...
- Bel JC. Pitfalls and limits of locking plates. Orthop Traumatol Surg Res. 2019;105:S103-S109.
Go to original source...
Go to PubMed...
- Borrelli J Jr, Prickett W, Song E, Becker D, Ricci W. Extraosseous blood supply of the tibia and the effects of different plating techniques: a human cadaveric study. J Orthop Trauma. 2002;16:691-695.
Go to original source...
Go to PubMed...
- Bottlang M, Doornink J, Fitzpatrick DC, Madey SM. Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength. J Bone Joint Surg Am. 2009;91:1985-1994.
Go to original source...
Go to PubMed...
- Bottlang M, Feist F. Biomechanics of Far Cortical Locking. J Orthop Trauma. 2011;25:21-28.
Go to original source...
Go to PubMed...
- Dráč P. Ovlivňuje stabilizace fibuly výsledky léčby zlomenin distální třetiny diafýzy tibie? Úraz Chir. 2005;13:39-44.
- Hasenboehler E, Rikli D, Babst R. Locking compression plate with minimally invasive plate osteosynthesis in diaphyseal and distal tibial fracture: a retrospective study of 32 patients. Injury. 2007; 38(3):365-70.
Go to original source...
Go to PubMed...
- Henschel J, Tsai S, Fitzpatrick DC, Marsh JL, Madey SM, Bottlang M. Comparison of 4 methods for dynamization of locking plates: differences in the amount and type of fracture motion. J Orthop Trauma. 2017;31:531-537.
Go to original source...
Go to PubMed...
- Huebner EJ, Iblher N, Kubosch DC, Suedkamp NP, Strohm PC. Zlomeniny dolního konce tibie a pilonu. Acta Chir Orthop Traumatol Cech. 2014;81:167-176
Go to original source...
Go to PubMed...
- Cheng W, Li Y, Manyi W. Comparison study of two surgical options for distal tibia fracture-minimally invasive plate osteosynthesis vs. open reduction and internal fixation. Int Orthop. 2011;35:737-742.
Go to original source...
Go to PubMed...
- Kvasnička P, Mašek M, Vojtaník P. Operační léčba zlomenin distálního bérce. Úraz Chir. 2012;20:116-124.
- Lau TW, Leung F, Chan CF, Chow SP. Wound complication of minimally invasive plate osteosynthesis in distal tibia fractures. Int Orthop. 2008;32:697-703.
Go to original source...
Go to PubMed...
- Li Y, Jiang X, Guo Q, Zhu L, Ye T, Chen A.Treatment of distal tibial shaft fractures by three different surgical methods: a randomized, prospective study. Int Orthop. 2014;38:1261-1267.
Go to original source...
Go to PubMed...
- Macnab I, De Haas WG. The role of periosteal blood supply in the healing of fractures of the tibia. Clin Orthop Relat Res. 1974;105:27-33.
Go to original source...
- Menck J, Bertram C, Lierse W. Sectorial angioarchitecture of the human tibia. Acta Anat (Basel). 1992;143:67-73.
Go to original source...
Go to PubMed...
- Nanavati N, Walker M. Current concepts to reduce mechanical stiffness in locked plating systems: a review article. Orthop Res Rev. 2014;6:91-95.
Go to original source...
- Newmana SDS, Mauffrey CPC, Krikler S. Distal metadiaphyseal tibial fractures. Injury. 2011; 42:975-984.
Go to original source...
Go to PubMed...
- Paluvadi SV, Lal H, Mittal D, Vidyarthi K. Management of fractures of the distal third tibia by minimally invasive plate osteosynthesis - a prospective series of 50 patients. J Clin Orthop Trauma. 2014;5:129-136.
Go to original source...
Go to PubMed...
- Rhinelander FW. Tibial blood supply in relation to fracture healing. Clin Orthop Relat Res. 1974; 105:34-81.
Go to original source...
- Sandoval JMC, Rueda JLO, Daza AS. Management of diaphyseal tibial fractures by plate fixation with absolute or relative stability: a retrospective study of 45 patients. Trauma Surg Acute Care Open. 2017;2:1-5.
Go to original source...
Go to PubMed...
- Santolini E, Goumenos SD, Giannoudi M, Sanguineti F, Stella M, Giannoudis PV. Femoral and tibial blood supply: a trigger for non-union? Injury. 2014;45:1665-1673.
Go to original source...
Go to PubMed...
- Trueta J. Blood supply and the rate of healing of tibial fractures. Clin Orthop Relat Res. 1974;105:11-26.
Go to original source...
- Vallier HA, Cureton BA, Patterson BM. Randomized, prospective comparison of plate versus intramedullary nail fixation for distal tibia shaft fractures. J Orthop Trauma. 2011;25:736-741.
Go to original source...
Go to PubMed...
- Vallier HA, Le TT, Bedi A. Radiographic and clinical comparisons of distal tibia shaft fractures (4 to 11 cm proximal to the plafond): plating versus intramedullary nailing. J Orthop Trauma. 2008;22:307-311.
Go to original source...
Go to PubMed...