Acta Chir Orthop Traumatol Cech. 2021; 88(2):101-106 | DOI: 10.55095/achot2021/018

Orbital Fractures in ChildrenOriginal papers

K. PERCEOVÁ1,*, ©. BIBROVÁ2, M. URÍK1, I. ©LAPÁK1, M. JURAJDA3, S. ©IKOLOVÁ1
1 Klinika dětské otorinolaryngologie, Fakultní nemocnice Brno a Lékařská fakulta Masarykovy univerzity, Brno
2 Klinika dětské chirurgie, ortopedie a traumatologie, Fakultní nemocnice Brno a Lékařská fakulta Masarykovy univerzity, Brno
3 Ústav patologické fyziologie, Lékařská fakulta Masarykovy univerzity, Brno

PURPOSE OF THE STUDY:
Diagnosis and treatment of fractures of the facial skeleton in children can be difficult due to the skeletal growth.

MATERIAL AND METHODS:
The 9-year retrospective study included patients admitted with the orbital fracture diagnosis to the University Hospital Brno, Children s Hospital, Department of Paediatric ENT, Department of Paediatric Anaesthesiology and Resuscitation, and Department of Paediatric Surgery, Orthopaedics and Traumatology. We looked into the number of patients admitted to the hospital with the orbital fracture diagnosis and the cause of the injury, the age of patients, and the used treatment method - surgical or non-operative treatment were analysed.
The following assumptions were applied:
1. Incidence of the injury (orbital fracture) increases with the age of the patient,
2. Incidence of the injury in individual years is constant.

RESULTS:
In the followed-up period, between 2010 and 2018, a total of 47 patients, of whom 8 girls and 39 boys, with the orbital fracture diagnosis were treated. 12 patients underwent surgery, 35 patients were treated non-operatively. The study group included 47 patients with the age range of 1 to 18 years, with the median age 12 years. When the results were processed, a trend was revealed showing an increase in the number of injuries as well as an in the age of patients at the time of injury. The number of injuries increases with age and year. Both the correlations, however, are statistically insignificant and the trend can be considered statistically insignificant.

DISCUSSION:
Both the non-operative and surgical treatment of patients lead to excellent results, even in the long-term follow-up. In paediatric patients, the surgical approach should be opted for only in cases when the non-operative approach is impossible due to the extent and characteristics of fracture and damage to soft tissues.

CONCLUSIONS:
The surgical treatment aims at the best possible anatomical reconstruction of the orbit with no subsequent functional or cosmetic defects. If surgical treatment is necessary, then the transconjunctival approach is most appropriate in children, namely because of the good overview over the operating field, simple procedure as well as the cosmetic outcome. In most cases it is enough to reposition the orbital soft tissues. In complicated cases, with an orbital floor defect, it needs to be covered with a suitable material.
Also, the non-operative approach has its place in therapy and the case-by-case approach must be applied.
Orbital fractures should always be treated by experienced specialists (ENT, dental surgeon, traumatologist) specialising in paediatric patients.

Keywords: fracture, orbit, childhood, surgical, non-operative treatment

Published: April 15, 2021  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
PERCEOVÁ K, BIBROVÁ ©, URÍK M, ©LAPÁK I, JURAJDA M, ©IKOLOVÁ S. Orbital Fractures in Children. Acta Chir Orthop Traumatol Cech. 2021;88(2):101-106. doi: 10.55095/achot2021/018. PubMed PMID: 33960922.
Download citation

References

  1. Allison JR, Kearns A, Banks RJ.Predicting orbital fractures in head injury: a preliminary study of clinical findings. Emerg Radiol. 2020;27:31-36. Go to original source... Go to PubMed...
  2. Davies R, Hammond D, Ridout F, Hutchison I, Magennis P. British Association of Oral and Maxillofacial Surgeons' National Facial Injury Surveys: hard tissue facial injuries presenting to UK emergency departments. Br J Oral Maxillofac Surg. 2020;58:152-157. Go to original source... Go to PubMed...
  3. Dennis P, Govind A, Demirel S, Amundson M. Orbital volume correction in orbital floor fractures: a comparison of transorbital and transantral techniques. J Oral Maxillofac Surg. 2020;78:430.e1-430.e7. Go to original source... Go to PubMed...
  4. Gál B, Hloľek J, Hloľková T, Slouka D, Kostřica R. Rekonstrukce izolovaných zlomenin spodiny očnice nazoseptální chrupavkou Acta Chir Orthop Traumatol Cech. 2019;86:72-76. Go to original source... Go to PubMed...
  5. Goyal S, Rettiganti M, Gupta P. Factors associated with motor vehicle-related eye injuries presenting to the US emergency departments. Eye (Basingstoke). 2020;34:755-762. Go to original source... Go to PubMed...
  6. Hwang K. Field management of facial injuries in sports. J Craniofac Surg. 2020;31:e179-e182. Go to original source... Go to PubMed...
  7. Jazayeri HE, Khavanin N, Yu JW, Lopez J, Ganjawalla KP, Shamliyan T, Tannyhill RJ.Dorafshar AH. Does early repair of orbital fractures result in superior patient outcomes? A systematic review and metaanalysis. J Oral Maxillofac Surg. 2020;78:568-577. Go to original source... Go to PubMed...
  8. Kohyama K, Arisawa K, Arisawa Y, Morishima Y. Symptomatic cystic lesions as late post-operative complications of silicone implantation for orbital wall fracture reconstruction: A long-term follow-up study. J Plast Reconstr Aesthet Surg. 2020;73:344-350 Go to original source... Go to PubMed...
  9. Mo YW, Kim SW, Shin HK. Prediction of late enophthalmos using quantitative measures in isolated medial orbital wall fracture: multiple regression analysis. J Plast Reconstr Aesthet Surg. 2020;73:576-585. Go to original source... Go to PubMed...
  10. Oliver JD, Saba ES,Gupta N, Hendricks TM, Singh DJ. Alloplastic reconstruction of orbital floor fractures: a systematic review and pooled outcomes analysis. Eur J Plast Surg. 2020;43:109-116. Go to original source...
  11. Smith B, Regan Jr WF. Blow-out fracture of the orbit. Mechanism and correction of internal orbital fracture. Am J Ophthalmol. 1957;44:733-739 Go to original source... Go to PubMed...
  12. Steinmassl O, Laimer J, Offermanns V, Wildauer M, Steinmassl PA, Grams AE, Kofler F, Rasse M, Bruckmoser E. Clinical outcome following surgical repair of small versus large orbital floor fractures using polyglactin 910/Polydioxanone (Ethisorb®). Materials. 2020;13:206 Go to original source... Go to PubMed...
  13. ©lapák I. Dětská otorinolaryngologie, 2. přepracované a doplněné vydání, Mladá fronta, Praha, 2019.
  14. Weadock WJ, Heisel CJ, Kahana A, Kim J. Use of 3D printed models to create molds for shaping implants for surgical repair of orbital fractures. Acad Radiol. 2020;27:536-542. Go to original source... Go to PubMed...