Acta Chir Orthop Traumatol Cech. 2021; 88(6):401-411 | DOI: 10.55095/achot2021/060

Reverse Total Shoulder Arthroplasty: 14-Year Clinical Experience with 496 Performed ArthroplastiesOriginal papers

D. POKORNÝ*, P. FULÍN, J. HEŘT, I. LANDOR, J. ŠTEFAN, A. SOSNA
1st Department of Orthopaedics, First Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic

PURPOSE OF THE STUDY:
Reverse total shoulder arthroplasty (RSA) can be considered a proven method for the treatment of the most severe shoulder joint affections. In this study, we present 14-year experiences of the authors with the LimaCorporate SMR® RSA system in 496 cases.

MATERIAL AND METHODS:
Included in the study are 496 RSAs performed between 2007 and 2020. We successfully followed up 368 shoulders in 358 patients. This was a prospective study with function being evaluated preoperatively and at the last follow-up in 2020. We evaluated the range of motion in active elevation and the classic Constant Score (CS). According to this score, the pain level was also evaluated. Standard statistical methods were used with a paired t-test used for comparisons of values.

RESULTS:
The mean follow-up in our group was 5.5 years (0.7-13.6, SD 3.22, median 4.96). Indications were: primary osteoarthritis (84), acute trauma (69), posttraumatic sequelae (79), cuff tear arthropathy (37), RA (29), chronic dislocations (18), final treatment of infectious complications (7), avascular necrosis (6), tumours (4) and TSA revisions (9).
The mean post-operative CS of all patients was 71.9 (2-94, SD 11.26, median 73). The mean post-operative active elevation was 127.35° (30°-180°, SD 28.36, median 130°). The mean pain level at final follow-up was 0.65 (0-3, SD 0.65, median 1). There was a statistically significant improvement In the CS (26.9 to 71) and the final achieved elevation (48.5° to 127.35°) in all groups except acute traumas for obvious reasons. A significant decrease in pain (2.8 to 0.65) was observed in all groups. We saw no implant failures or UHMWPE component wear.

DISCUSSION:
We compared our results with those published by other authors. When considering the functional outcomes, our results are comparable with those published previously.
Compared to other studies, an interesting result is the low incidence of scapular notching. In our cohort of patients, it was only present in 10 (2.7%) cases. We attribute this to the design of the SMR® implant which meets the main criterium of a modern shoulder arthroplasty system: modularity of both glenoid components. The glenospheres are available in 36, 40 and 44mm sizes with standard and distalised options. Furthermore, the system also contains the Axioma® revision glenoid component. Humeral stems are available in a range of sizes and lengths including revision stems. The humeral body is also available in two sizes. The short variant is optimal for revision with hemiarthroplasty to reverse conversion.

CONCLUSIONS:
During a period of 14 years, we performed 496 implantations of RSAs using the SMR® system. We evaluated 368 cases with an average follow-up of 5.5 years. During long-term follow-up we experienced no implant failures or complications indicative of any constructional insufficiencies. We saw no signs of UHMWPE liner wear. The SMR® system allows for treatment of even the most complex shoulder affections due to its high modularity.

Keywords: shoulder joint replacement, reverse shoulder arthroplasty, SMR®, Axioma®, outcomes, ROM, scapular notching, complication, polyethylene wear, UHMWPE

Published: December 15, 2021  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
POKORNÝ D, FULÍN P, HEŘT J, LANDOR I, ŠTEFAN J, SOSNA A. Reverse Total Shoulder Arthroplasty: 14-Year Clinical Experience with 496 Performed Arthroplasties. Acta Chir Orthop Traumatol Cech. 2021;88(6):401-411. doi: 10.55095/achot2021/060. PubMed PMID: 34998442.
Download citation

References

  1. Al-Hadithy N, Domos P, Sewell MD. Reverse shoulder arthroplasty in 41 patients with cuff tear arthropathy with a mean follow-up period of 5 years. J Shoulder Elbow Surg. 2014;23:1662-1668. Go to original source... Go to PubMed...
  2. Ball, CM. Delta Xtend reverse shoulder arthroplasty - results at a minimum of five years. Shoulder Elbow. 2020;12:114-123. Go to original source... Go to PubMed...
  3. Bassens D, Decock T, Tongel A, De Wilde L. Long-term results of the Delta Xtend reverse shoulder prosthesis. J Shoulder Elbow Surg. 2019;28:1091-1097. Go to original source... Go to PubMed...
  4. Beltrame A, Di Benedetto P, Salviato D, Niccoli G, Gisonni R, Cainero V, Causero A. The SMR reverse shoulder arthroplasty in rotator cuff arthropathy management. Acta Biomed. 2017;88:81-89.
  5. Boileau P. Complications and revision of reverse total shoulder arthroplasty. Orthop Traumatol Surg Res. 2016;102:33-43. Go to original source... Go to PubMed...
  6. Cazeneuve JF, Hassan Y, Kermad F, Brunel A. Delta III reverse-ball-and-socket total shoulder prosthesis for acute complex fractures of the proximal humerus in elderly. Eur J Orthop Surg Traumatol. 2008;18:81-86. Go to original source...
  7. Cofield RH, Stauffer RN. The Bickel glenohumeral arthroplasty. In: Morrey BF, ed. Conference on Joint Replacement in the Upper Limb. Institute of Mechanical Engineering, London, UK, 1977, pp.15-25.
  8. Constant CR, Murley AHG. A clinical method of functional assesment of the shoulder. Clin Orthop Relat Res. 1987;214:160-164. Go to original source...
  9. Coughlin MJ, Morris JM, West WF. The semiconstrained total shoulder arthroplasty. J Bone Joint Surg Am. 1979;61:574-581. Go to original source... Go to PubMed...
  10. Flatow EL, Harrison AK. A history of reverse total shoulder arthroplasty. Clin Orthop Relat Res. 2011;469:2432-2439. Go to original source... Go to PubMed...
  11. Frankle M., Siegal S., Pupello D., Saleem A., Mighell M., Vasey M. The reverse shoulder prosthesis for glenohumeral arthritis associated with severe rotator cuff deficiency. A minimum two-year follow-up study of sixty patients. J Bone Joint Surg Am. 2005;87:1697-705. Go to original source... Go to PubMed...
  12. Gallo RA, Gamradt SC, Mattern CJ. Instability after reverse total shoulder replacement. J Shoulder Elbow Surg. 2011;20:584-590. Go to original source... Go to PubMed...
  13. Grammont P, Trouilloud P, Laffay J, Deries X. Concept study and realization of a new total shoulder prosthesis. Rheumatologie. 1987;39:407-418.
  14. Harman M, Frankle M, Vasey M, Banks S. Initial glenoid component fixation in ''reverse'' total shoulder arthroplasty: A biomechanical evaluation. J Shoulder Elbow Surg. 2005;14:162-167. Go to original source... Go to PubMed...
  15. http://www.fhortho.com
  16. https://www.fxsolutions.fr
  17. Chalmers PN, Rahman Z, Romeo AA. Early dislocation after reverse total shoulder arthroplasty. J Shoulder Elbow Surg. 2014;23:737-744. Go to original source... Go to PubMed...
  18. Chou J, Malak SF, Anderson IA, Astley T, Poon PC. Biomechanical evaluation of different designs of glenospheres in the SMR reverse total shoulder prosthesis: range of motion and risk of scapular notching. J Shoulder Elbow Surg. 2009;18:354-359. Go to original source... Go to PubMed...
  19. Jacquot A, Sirveaux F, Roche O. Surgical management of the infected reversed shoulder arthroplasty: a French multicenter study of reoperation in 32 patients. J Shoulder Elbow Surg. 2015;24:1713-1722. Go to original source... Go to PubMed...
  20. Jahoda D, Pokorný D, Nyc O, Barták V, Hromádka R, Landor I, Sosna A. Infectious complications of total shoulder arthroplasty. Acta Chir Orthop Traumatol Cech. 2008;75:422-428. Go to original source... Go to PubMed...
  21. Kelly JD, Zhao JX, Hobgood ER. Clinical results of revision shoulder arthroplasty using the reverse prosthesis. J Shoulder Elbow Surg. 2012;21:1516-1525. Go to original source... Go to PubMed...
  22. Kenmore PI, MacCartee C, Vitek B. A simple shoulder replacement. J Biomed Mater Res. 1974;8: 329-330. Go to original source... Go to PubMed...
  23. Kessel L, Bayley I. Prosthetic replacement of shoulder joint: preliminary communication. J R Soc Med. 1979;72:748-752. Go to original source... Go to PubMed...
  24. Ko JK, Tompson JD, Sholder DS. Heterotopic ossification of the long head of the triceps after reverse total shoulder arthroplasty. J Shoulder Elbow Surg. 2016;25:1810-1815. Go to original source... Go to PubMed...
  25. Lädermann A, Schwitzguebel AJ, Edwards TB, Godeneche A, Favard L, Walch G, Sirveaux F, Boileau P, Gerber C. Glenoid loosening and migration in reverse shoulder arthroplasty. Bone Joint J. 2019;101-B:461-469. Go to original source... Go to PubMed...
  26. Marmor L. Hemiarthroplasty for the rheumatoid shoulder joint. Clin Orthop Relat Res. 1977;122:201-203. Go to original source...
  27. Morris BJ, O'Connor DP, Torres D. Risk factors for periprosthetic infection after reverse shoulder arthroplasty. J Shoulder Elbow Surg. 2015;24:161-166. Go to original source... Go to PubMed...
  28. Neer CS 2nd, Craig EV, Fukuda H. Cuff-tear arthropathy. J Bone Joint Surg Am. 1983;65:1232-1244. Go to original source... Go to PubMed...
  29. Neer CS 2nd, Watson KC, Stanton FJ. Recent experience in total shoulder replacement. J Bone Joint Surg Am. 1982;64:319-337. Go to original source... Go to PubMed...
  30. Neer CS 2nd. Articular replacement for the humeral head. J Bone Joint Surg Am. 1955;37:215-228. Go to original source... Go to PubMed...
  31. Neer CS 2nd. Replacement arthroplasty for glenohumeral osteoarthritis. J Bone Joint Surg Am. 1974;56:1-13. Go to original source... Go to PubMed...
  32. Neer CS 2nd. Shoulder Reconstruction. WB Saunders, Philadelphia, 1990.
  33. Nyffeler RW, Werner CM, Gerber C. Biomechanical relevance of glenoid component positioning in the reverse Delta III total shoulder prosthesis. J Shoulder Elbow Surg. 2005;14:524-528. Go to original source... Go to PubMed...
  34. Ongaro R, Grisandi S. Lualdi - Lima: the story-focus on the man. LimaCorporate, Udine, 2009.
  35. Ramirez MA, Lu Y, Schaver A. Catastrophic failure of reverse shoulder arthroplasty from a broken screw: a case report. J Bone Joint Surg Case Connect. 2020;10:e19.00504. Go to original source... Go to PubMed...
  36. Rittmeister M, Kerschbaumer F. Grammont reverse total shoulder arthroplasty in patients with rheumatoid arthritis and nonreconstructible rotator cuff lesions. J Shoulder Elbow Surg. 2001;10:17-22. Go to original source... Go to PubMed...
  37. Rojas J, Choi K, Joseph J, Srikumaran U, McFarland EG. Aseptic glenoid baseplate loosening after reverse total shoulder arthroplasty: a systematic review and meta-analysis. JBJS Rev. 2019;7:e7. Go to original source... Go to PubMed...
  38. Simovitch RW, Zumstein MA, Lohri E, Helmy N, Gerber C. Predictors of scapular notching in patients managed with the Delta III reverse total shoulder replacement. J Bone Joint Surg Am. 2007; 89:588-600. Go to original source... Go to PubMed...
  39. Sirveaux F, Favard L, Oudet D, Huquet D,Walch C, Mole' D. Grammont inverted total shoulder arthroplasty in the treatment of glenohumeral osteoarthritis with massive rupture of the cuff. Results of a multicentre study of 80 shoulders. J Bone Joint Surg Br. 2004;86:388-395. Go to original source... Go to PubMed...
  40. Stephens BC, Simon P, Clark RE, Christmas KN, Stone GP, Lorenzetti AJ, Frankle MA. Revision for a failed reverse: a 12-year review of a lateralized implant. J Shoulder Elbow Surg. 2016;25:115-124. Go to original source... Go to PubMed...
  41. Stroud N, DiPaola MJ, Flurin PH, Roche CHP. Reverse shoulder glenoid loosening: an evaluation of the initial fixation associated with six different reverse shoulder designs. Bull Hosp Jt Dis. 2013;71(Suppl 2):S12-S17. Go to PubMed...
  42. Tanner MW, Cofield RH. Prosthetic arthroplasty for fractures and fracture-dislocations of the proximal humerus. Clin Orthop Relat Res. 1983;179:116-128. Go to original source...
  43. Valenti PH, Boutens D, Nerot C. Delta 3 reversed prosthesis for osteoarthritis with massive rotator cuff tear: long term results (5 years). In: Walch G, Boileau P, Mole' D (eds). 2000 Prostheses depaule.recul de 2 a 10 ans. Sauramps Medical, Paris, 2001, pp.253-259.
  44. Vanhove B, Beugnies A. Grammont's reverse shoulder prosthesis for rotator cuff arthropathy. A retrospective study of 32 cases. Acta Orthop Belg. 2004;70:219-225. Go to PubMed...
  45. Werner CM, Steinmann PA, Gilbart M, Gerber C. Treatment of painful pseudoparesis due to irreparable rotator cuff dysfunction with the Delta III reverse-ball-and-socket total shoulder prosthesis. J Bone Joint Surg Am. 2005;87:1476-1486. Go to original source... Go to PubMed...
  46. Young SW, Everts NM, Ball CM, Astley TM, Poon PC. The SMR reverse shoulder prosthesis in the treatment of cuff-deficient shoulder conditions. J Shoulder Elbow Surg. 2009;18:622-626. Go to original source... Go to PubMed...
  47. Zumstein MA, Pinedo M, Old J. Problems, complications, reoperations, and revisions in reverse total shoulder arthroplasty: a systematic review. J Shoulder Elbow Surg. 2011;20:146-157. Go to original source... Go to PubMed...