Acta Chir Orthop Traumatol Cech. 2010; 77(2):134-139 | DOI: 10.55095/achot2010/025

Uvolnění šroubů po zadní dynamické stabilizaci - přehled literaturyPůvodní práce

T. KOCAK*, B. CAKIR, H. REICHEL, T. MATTES
Department of Orthopedics, University of Ulm, Germany

PURPOSE OF THE STUDY:
The malposition of pedicle screws in the lumbar spine is associated with a potential risk of iatrogenic injury of neurological structures but also with a decrease of biomechanical stability. The correct position of the pedicle screws of a dynamic stabilization device, as a long-term implant, seems to be of great importance. A high incidence of screw loosening could influence both the rate of revision surgeries and the clinical results. We compared screw loosening in our own patients with published data after navigated and non-navigated implantation of Dynesys.

MATERIAL AND METHODS:
Posterior instrumentation with the Dynesys system was performed in 19 patients after improvement of facet joint infiltrations. Seven (37 %) patients underwent conventional surgery (group I), five (26 %) were operated on using a CT-based navigation (group II) and seven (37 %) using a fluoroscopic-based navigation (group III). Pre-operatively, the "Oswestry Low Back Pain Disability Questionnaire (OQ)" and the "Short Form 36 Health Survey Questionnaire (SF-36)" were used to obtain pain and functional scores. Furthermore, radiographs, MRI and CT examinations were performed before surgery. Screw position was analyzed on post-operative CT scans. At a minimum follow-up of twelve months, clinical examination, plain and dynamic X-rays were performed, and pain and functional scores (OQ, SF-36) were obtained.

RESULTS:
Pedicle perforation of minimum 2 mm was detected in two group I patients, in one group II and in two group III patients. Regarding OQ and SF-36, an improvement was observed in all patients, except for one column of SF-36. One patient (group I) underwent revision surgery due to symptomatic screw loosening and another patient (group III) due to persistent pain without signs of screw loosening.

DISCUSSION:
In former publications the majority of patients improved after Dynesys implantation with or without the use of navigation methods. Malposition of screws was not always followed by screw loosening. Revision surgery due to screw loosening, but without clinical symptoms, was not necessary in the majority of cases.

CONCLUSIONS:
It still remains unclear if screw loosening after Dynesys implantation influences the clinical results or the rate of revision surgery and if malposition of screws will be followed by a higher rate of screw loosening.

Klíčová slova: dynamic stabilization, Dynesys screw loosening navigation lumbar spine

Zveřejněno: 1. duben 2010  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
KOCAK T, CAKIR B, REICHEL H, MATTES T. Uvolnění šroubů po zadní dynamické stabilizaci - přehled literatury. Acta Chir Orthop Traumatol Cech. 2010;77(2):134-139. doi: 10.55095/achot2010/025. PubMed PMID: 20447357.
Stáhnout citaci

Reference

  1. AMIOT, L. P., LANG, K., PUTZIER, M., ZIPPEL, H., LABELLE, H.: Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar and sacral spine. Spine, 25: 606-614, 2000. Přejít k původnímu zdroji... Přejít na PubMed...
  2. CAKIR, B., RICHTER, M., HUCH, K., PUHL, W., SCHMIDT, R.: Dynamic stabilization of the lumbar spine. Orthopedics, 29: 716-722, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  3. CASTRO, W. H., HALM, H., JEROSCH, J., MALMS, J., STEINBECK, J., BLASIUS, S.: Accuracy of pedicle screw placement in lumbar vertebrae. Spine, 21: 1320-1324, 1996. Přejít k původnímu zdroji... Přejít na PubMed...
  4. EBMEIER, K., GIEST, K., KALFF, R.: Intraoperative Computerized Tomography for Improved Accuracy of Spinal Navigation in Pedicle Screw Placement of the Thoracic Spine. Acta Neurochir., 85: 105-113, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  5. FOLEY, K. T., RAMPERSAUD, Y. R., SIMON, D. A.: Virtual fluoroscopy: computerassisted fluoroscopic navigation. Spine, 26: 341-351, 2001. Přejít k původnímu zdroji... Přejít na PubMed...
  6. FRITSCH, E., DUCHOW, J., SEIL, R., GRUNWALD, I., REITH, W.: Accuracy of fluoroscopic navigation of pedicle screws. CT-based evaluation of bone screw placement. Orthopäde, 31: 385-391, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  7. GROB, D., BENINI, A., JUNGE, A., MANNION, A. F.: Clinical experience with the Dynesys semirigid fixation system for the lumbar spine: surgical and patient-oriented outcome in 50 cases after an average of 2 years. Spine, 30: 324-331, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  8. KORGE, A., NYDEGGER, T., POLARD, J. L., MAYER, H. M., HUSSON, J. L. : A spiral implant as nucleus prosthesis in the lumbar spine. Europ. Spine J., 11: 149-153, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  9. LAINE, T., LUND, T., YLIKOSKI, M., LOHIKOSKI, J., SCHLENZKA, D.: Accuracy of pedicle screw insertion with and without computer assistance: a randomised controlled clinical study in 100 consecutive patients. Europ. Spine J., 9: 235-240, 2000. Přejít k původnímu zdroji... Přejít na PubMed...
  10. LONSTEIN, J. E., DENIS, F., PERRA, J. H., PINTO, M. R., SMITH, M. D., WINTER, R. B.: Complications associated with pedicle screws. J. Bone Jt Surg., 81-A: 1519-1528, 1999. Přejít k původnímu zdroji... Přejít na PubMed...
  11. MATEJKA, J., ZEMAN, J., BELATKA, J.: Mid-term results of 360-degree lumbar spondylodesis with the use of a tantalum implant for disc replacement. Acta Chir. orthop. Traum. čech., 76: 388-393, 2009. Přejít k původnímu zdroji...
  12. MAYER, H. M., WIECHERT, K., KORGE, A. QOSE, I.: Minimally invasive total disc replacement: surgical technique and preliminary clinical results. Europ. Spine J., 11: 124-130, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  13. NEMEC, F., CHALOUPKA, R., KRBEC, M., MESSNER, P.: Evaluation of the quality of life in patients with degenerative disorders of lumbar spine. Acta Chir. Orthop. Traum. čech., 76: 20-24, 2009. Přejít k původnímu zdroji...
  14. PIHLAJÄMAKI, H., MYLLYNEN, P., BÖSTMAN, O.: Complications of transpedicular lumbosacral fixation for non-traumatic disorders. J. Bone Jt Surg. 79-B: 183-189, 1997. Přejít k původnímu zdroji...
  15. PUTZIER, M., SCHNEIDER, S. V., FUNK, J., PERKA, C.: Application of a dynamic pedicle screw system (DYNESYS) for lumbar segmental degenerations - comparison of clinical and radiological results for different indications. Z. Orthop., 142: 166-173, 2004. Přejít k původnímu zdroji... Přejít na PubMed...
  16. PUTZIER, M., SCHNEIDER, S. V., FUNK, J. F., TOHTZ, S. W., PERKA, C.: The surgical treatment of the lumbar disc prolapse: nucleotomy with additional transpedicular dynamic stabilization versus nucleotomy alone. Spine, 30: 109-114, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  17. RAY, C. D.: The PDN prosthetic disc-nucleus device. Europ. Spine J., 11: 137-142, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  18. SCHNAKE, K. J., SCHAEREN, S., JEANNERET, B.: Dynamic stabilization in addition to decompression for lumbar spinal stenosis with degenerative spondylolisthesis. Spine, 31: 442-449, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  19. SEBESTA, P., STULÍK, J., VYSKOCIL, T., KRYL, J.: Posterior stabilization of L5 burst fractures without reconstruction of the anterior column. Acta Chir. orthop. Traum. čech., 75: 123-128, 2008. Přejít k původnímu zdroji...
  20. STOLL, T. M., DUBOIS, G., SCHWARZENBACH, O.: The dynamic neutralization system for the spine: a multi-center study of a novel non-fusion system. Europ. Spine J., 11: 170-178, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  21. SWANSON, K. E., LINDSEY, D. P., HSU, K. Y., ZUCHERMAN, J. F., YERBY, S. A.: The effects of an interspinous implant on intervertebral disc pressures. Spine, 28: 26-32, 2003. Přejít k původnímu zdroji... Přejít na PubMed...