Acta Chir Orthop Traumatol Cech. 2010; 77(2):143-148 | DOI: 10.55095/achot2010/027
A Palmar Percutaneous Volar versus a Dorsal Limited Approach for the Treatment of Non- and Minimally-Displaced Scaphoid Waist Fractures: An Assessment of Functional Outcomes and ComplicationsOriginal papers
- 1 Traumatologické oddělení FN Olomouc
- 2 Radiologická klinika FN Olomouc
- 3 Ústav lékařské biofyziky, biometrie a informatiky, LF UP Olomouc
PURPOSE OF THE STUDY:
Non-displaced or minimally displaced scaphoid waist fractures can be surgically treated using either the percutaneous volar or the limited dorsal approach. These techniques provide a possibility of early wrist physiotherapy throughout the healing period, better functional outcomes and a shorter sick leave duration. Many reports cite low complication rates. The purpose of this study is to compare both techniques based on the complication rate and functional outcomes.
MATERIAL AND METHODS:
The authors compared 42 patients treated for an acute scaphoid waist fracture by percutaneous osteosynthesis and 38 patients treated by osteosynthesis using a limited dorsal approach after a follow-up of at least 12 months. The differences between the groups were tested statistically.
RESULTS:
The overall complication rate was 11.9% for the percutaneous approach and 15.8% for the dorsal approach. There was one case of non-union in each group. The differences in the complication rates as well as in the range of wrist motion and in persistent complaints were statistically insignificant. We found significantly (p = 0.042) better grip strength for the percutaneous approach.
DISCUSSION:
Most of the complications detected were due to a technical error during surgery and can be minimized by meticulous adherence to the technique. The difference in grip strength is very close to the significance level set for the study, and this will be necessary to clarify in a planned prospective study.
CONCLUSIONS:
Based on the statistical analysis of the results of our clinical data, the two techniques are comparable.
Keywords: scaphoid fractures, palmar percutaneous approach, dorsal limited approach, functional outcome, complications
Published: April 1, 2010 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- ADAMANI, D. C., MIKOLA, E. A., FRASER, B. J.: Percutaneous fixation of the scaphoid through a dorsal approach: an anatomic study. J. Hand Surg., 33-A: 327-331, 2008.
Go to original source...
Go to PubMed...
- ADOLFSON, L., LINDAU, T., ARNER, M.: Acutrak screw fixation versus cast immobilisation for undisplaced scaphoid waist fractures. J. Hand Surg., 26-B: 192-195, 2001.
Go to original source...
Go to PubMed...
- BEDI, A., JEBSON, P. J. L., HAYDEN, R. J., JACOBSON, J. A., MARTUS, J. E.: Internal fixation of acute, nondisplaced scaphoid waist fracture via a limited dorsal approach: an assessment of radiographic and functional outcomes. J. Hand Surg., 32-A: 326-333, 2007.
Go to original source...
Go to PubMed...
- BEREDJIKLIAN, P. K., BOZENTKA, D. J., LEUNG, Y. L., MONAGHAN, B. A.: Complications of wrist arthroscopy. J. Hand Surg. 29-A: 406-411, 2004.
Go to original source...
Go to PubMed...
- BOND, C. D., SHIN A. Y., McBRIDE, M. T., DAO. K. D.: Percutaneous screw fixation or cast immobilization for nondisplaced scaphoid fractures. J. Bone Jt Surg., 83-A: 483-488, 2001.
Go to original source...
Go to PubMed...
- BUSHNELL, B. D., McWILLIAMS, A. D., MESSER, T. M.: Complications in dorsal percutaneous cannulated screw fixation of nondisplaced scaphoid waist fracture. J. Hand Surg., 32-A: 827-833, 2007.
Go to original source...
Go to PubMed...
- CHAN, K. W., McADAMS, T. R.: Central screw placement in percutaneous screw scaphoid fixation: a cadaveric comparision of proximal and distal techniques. J. Hand Surg., 29-A: 74-79, 2004.
Go to original source...
Go to PubMed...
- DeMAAGD, R. L., ENGBER, W. D.: Retrograde Herbert screw fixation for treatment of proximal pole scaphoid nonunions. J. Hand Surg., 14-A: 996-1003, 1989.
Go to original source...
Go to PubMed...
- DRÁČ, P., MAŇÁK, P., LABÓNEK, I.: Percutaneous osteosynthesis versus cast immobilisation for the treatment of minimally and non-displaced scaphoid fractures. Functional outcomes after a follow-up of at least 12 month. Biomed. Papers, 149: 149-151, 2005.
Go to original source...
Go to PubMed...
- DRÁČ, P., MAŇÁK, P., LABÓNEK, I., BENÝ©EK, V.: Perkutánní osteosyntéza zlomenin člunkové kosti - předběľné výsledky. Acta Chir. orthop. Traum. čech., 71: 165-170, 2004.
- DRÁČ, P.: Osteosyntéza zlomenin člunkové kosti z limitovaného dorzálního přístupu. Úraz. chir., 14: 103-108, 2006.
- HADDAD, F. S., GODDARD, N. J.: Acute percutaneous scaphoid fixation. J. Bone Jt Surg., 80-B: 95-99, 1998.
Go to original source...
- HERBERT, T. J.: The fractured scaphoid. St Louis, Quality Medical Publishing, Inc. 1990.
- KAMINENI, S., LAVY, C. B. Percutaneous fixation of scaphoid fractures. An anatomical study. J. Hand Surg., 24-B: 85-88, 1999.
Go to original source...
Go to PubMed...
- LISÝ, M., PINK, M., SKLÁDAL, M., VAŇO, M. Tenodéza - řeąení chronické nestability distálního radioulnárního kloubu. Acta Chir. orthop. Traum čech., 76: 35-40, 2009.
Go to original source...
- MARTUS, J. E., BEDI, A., JEBSON, P.J. L.: Cannulated variable pitch compression screw fixation of scaphoid fractures using a limited dorsal approach. Tech. Hand Up. Extr. Surg., 9: 202-206, 2005.
Go to original source...
Go to PubMed...
- McCALLISTER, W. V., KNIGHT, J., KALIAPPAN, R., TRUMBLE, T. E.: Central placement of the screw in simulated fractures of the scaphoid waist: a biomechanical study. J. Bone Jt Surg., 85-A: 72-77, 2003.
Go to original source...
Go to PubMed...
- MÜLLER, M., GERMANN, G., SAUERBIER, M.: Minimal invasive screw fixation and early mobilization of acute scaphoid fractures in the middle third: operative technique and early functional outcome. Tech. Hand Up. Extr. Surg., 12: 107-113, 2008.
Go to original source...
Go to PubMed...
- PILNÝ, J., ©VARC, A., PEŘINA, M., ©ILLER, J., VI©ŇA, P. Chronické lunotriquetrální nestability zápěstí - vlastní metoda oąetření. Acta Chir. orthop. Traum. čech., 76: 208-211, 2009.
Go to original source...
- PIRELA-CRUZ, M. A., BATTISTA, V., BURNETTE, S., HANSEN, T.: A technical note on percutaneous scaphoid fixation using a hybrid technique. J. Orthop. Trauma, 19: 570-573, 2005.
Go to original source...
Go to PubMed...
- SAEDÉN, B., TÖRNKVIST, H., PONZER, S., HÖGLUND, M.: Fracture of the carpal scaphoid. A prospective, randomised 12-year follow-up comparing operative and conservative treatment. J. Bone Jt Surg., 83-B: 230-234, 2002.
Go to original source...
- SLADE3rd, J. F., GRAUER, J. N., MAHONEY, J. D: Arthroscopic reduction and percutaneous fixation of scaphoid fractures with a novel dorsal technique. Orth. Clin. N. Amer., 30: 247-261, 2001.
Go to original source...
Go to PubMed...
- SLADE3rd, J. F., GUTOW, A. P., GEISSLER, W. B.: Percutaneous internal fixation of scaphoid fractures via an arthroscopically assisted dorsal approach. J. Bone Jt Surg., 84-A: Suppl 2, 21-36, 2002.
Go to original source...
Go to PubMed...
- STRELI, R.: Perkutane Verschraubung des Handkahnbeines mit Bohrdraht-Kompressionsschraube. Zbl. Chir., 95: 1060-1078, 1970.
- YIP, H. S. P., WU, W. C., CHANG, R. Y. P., SO, T. Y. C.: Percutaneous cannulated screw fixation of acute scaphoid waist fracture. J. Hand Surg., 27-B: 42-46, 2002.
Go to original source...
Go to PubMed...
- ZAIDEMBERG, C., SIEBERT, J., ANGRIGIANI, C.: A new vascularized bone graft for scaphoid nonunion. J. Hand Surg., 16-A: 474-478, 1991.
Go to original source...
Go to PubMed...