Acta Chir Orthop Traumatol Cech. 2012; 79(6):529-534 | DOI: 10.55095/achot2012/077

Zlomeniny distálního humeru AO 13 C - výsledky operační léčbyPůvodní práce

K. HOLUB*, M. KLOUB, P. KOPAČKA
Oddělení úrazové chirurgie Nemocnice České Budějovice

PURPOSE OF THE STUDY:
The aim of this retrospective study was to evaluate the results of surgical treatment in 41 fractures of the distal humerus classified as type C according to the AO system using conventional versus angle-stable locking plates.

MATERIAL:
Fifty-one patients were treated by the open reduction and internal fixation method at our department between 2005 and 2008. The group included 28 women and 23 men with an average age of 52.5 years. Forty-one patients came to the final treatment evaluation. The average follow-up was 19 months. Of the 41 injuries, 34% were open fractures.

METHODS:
All patients were operated on from the standard dorsal approach. Olecranon osteotomy was performed in 83% and the Bryan-Morrey procedure was used in 17% of the patients. Stable osteosynthesis with two reconstruction plates was used in 14 patients (34%), two locking distal humeral plates (DHP) in 21 patients (51%) and a reconstruction plate combined with a DHP was employed in six patients (15%). Controlled early passive rehabilitation was started as soon as acute pain after surgery had resolved. Follow-up at 4, 8 and 12 weeks and at 6 and 12 months included clinical and radiographic examination. The functional outcome was assessed using the Mayo Elbow Performance Score (MEPS) system.

RESULTS:
The average MEPS was 83.6 points. Excellent results were recorded in 19 (46%), good in 14 (34%), satisfactory in five (12%) and poor in three (8%) patients.
Healing was achieved within 3 months of surgery in 82% and within 4 months in 12% of the patients. Non-union due to failure of osteosynthesis was recorded in 5 % of the patients. No differences were found in the duration of healing in relation to the implant used. The average flexion/extension range of motion (ROM) at the elbow was 108 degrees (range, 40 to 145 degrees).
The complications included failure of osteosynthesis in three patients, deep wound infection in two, superficial infection in one and heterotopic ossification in five patients. Of 16 patients (39%) with ulnar nerve irritation, 15 had impairment in sensory function and one in motor function. The average operative time was 163 min.

DISCUSSION:
The results of our study correspond to relevant data reported in the present-day literature. There is an agreement in excellent and good functional outcomes, as assessed using the MEPS, in ROM values and operative time as well as in complications such as non-union, infection or heterotopic ossification. Compared with other studies, the proportion of ulnar nerve irritation in our group was higher. As reported, excellent results are achieved with the use of locking compression plates, particularly in comminuted fractures of the distal humerus in osteoporotic bone.

CONCLUSIONS:
The method of open reduction and internal fixation with two plates performed by an experienced surgeon brings about good results in the treatment of AO type C fractures of the distal humerus.

Klíčová slova: distal humerus, open reduction and internal fixation

Zveřejněno: 1. prosinec 2012  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
HOLUB K, KLOUB M, KOPAČKA P. Zlomeniny distálního humeru AO 13 C - výsledky operační léčby. Acta Chir Orthop Traumatol Cech. 2012;79(6):529-534. doi: 10.55095/achot2012/077. PubMed PMID: 23286686.
Stáhnout citaci

Reference

  1. ARNANDER, M.W., REEVES, A., MACLEOD, I.A., PINTO, T.M., KHALEEL, A.: A biomechanical comparison of plate configuration in distal humerus fractures. J. Orthop. Trauma, 22: 332-336, 2008 Přejít k původnímu zdroji... Přejít na PubMed...
  2. ASLAM, N., WILLETT, K.: Functional outcome following internal fixation of intraarticular fractures of the distal humerus (AO type C). Acta Orthop. Belg., 70: 118-122, 2004.
  3. BRYAN, R.S., MORREY, B.F.: Extensive posterior exposure of the elbow. A triceps sparing approach. Clin. Orthop., 166: 188-189, 1982. Přejít k původnímu zdroji...
  4. COLES, C.P., BAREI, D.P., NORK, S.E., TAITSMAN, L.A., HANEL, D.P., BRADFORD HENLEY, M.: The olecranon osteotomy: a six-year experience in the treatment of intraarticular fractures of the distal humerus.J. Orthop.Trauma, 20: 164-171, 2006. Přejít k původnímu zdroji... Přejít na PubMed...
  5. GEORGIADES, CH., MATĚJKA, J., PAVELKA, T., HOUČEK, P.: Výsledky léčby zlomenin distálního humeru otevřenou repozicí a vnitřní fixací LCP-DHS. Acta Chir. orthop.Traum. čech.,77: 479-483, 2010.
  6. GREINER, S., HAAS, N.P., BAIL, H.J.: Outcome after open reduction and angular stable internal fixation for supra-intercondylar fractures of the distal humerus: preliminary results with the LCP distal humerus system. Arch. Orthop. Trauma Surg.,128: 723-729, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  7. GUPTA, R.: Intercondylar fractures of the distal humerus in adults. Injury, 27: 569-572, 1996. Přejít k původnímu zdroji... Přejít na PubMed...
  8. HUANG, T.L., CHIU, F.Y., CHUANG, T.Y., CHEN, T.H.: Surgical treatment of acute displaced fractures of adult distal humerus with reconstruction plate. Injury, 35: 1143-1148, 2004. Přejít k původnímu zdroji... Přejít na PubMed...
  9. ILYAS, A.M., JUPITER, J.B.: Treatment of distal humerus fractures. Acta Chir. orthop. Traum. čech., 75: 6-15, 2008. Přejít k původnímu zdroji...
  10. Jupiter, J.B., Neff, U., Holzach, P., Allgöwer, M.: Intercondylar fractures of the humerus. An operative approach. J. Bone Jt Surg., 67-A: 226-239, 1985. Přejít k původnímu zdroji...
  11. KORNER, J., DIEDERICHS,G., ARZDORF, M., LILL, H., JOSTEN, C., SCHNEIDER, E., LINKE, B.: A biomechanical evaluation of methods of distal humerus fracture fixation using locking compression plates versus conventional reconstruction plates. J. Orthop. Trauma, 18: 286-293, 2004. Přejít k původnímu zdroji... Přejít na PubMed...
  12. KORNER, J., LILL, H., MÜLLER, L.P., HESSMANN, M., KOPF, K., GOLDHAHN, J., GONSCHOREK, O., JOSTEN, C., ROMMENS, P.M.: Distal humerus fractures in elderly patients: results after open reduction and internal fixation. Osteoporos Int.; 16 Suppl. 2: S73-79, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  13. KUNDEL, K., BRAUN,W.,WIEBERNEIT, J., RUTER, A.: Intraarticular distal humerus fractures.Factors affecting functional outcome. Clin. Orthop. Relat. Res., 332.2000-2008, 1996. Přejít k původnímu zdroji... Přejít na PubMed...
  14. LIU, J.J., RUAN, H.J., WANG, J.G., FAN, C.Y., ZENG, B.F.: Double-column fixation for type C fractures of the distal humerus in the elderly. Shoulder Elbow Surg., 18: 646-651, 2009. Přejít k původnímu zdroji... Přejít na PubMed...
  15. MORREY, B.F., AN, K.N., CHAO, E.Y.S.: Functional evaluation of the elbow. In The elbow and its disorders, edited by B. F. Morrey. Ed. 2, pp. 86-89. Philadelphia, W. B. Saunders, 1993.
  16. O'DRISCOLL, S.W.: Optimizing stability in distal humeral fracture fixation. J. Shoulder Elbow Surg., 14(1 Suppl S): 186S-194S, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  17. PAJARINEN, J., BJÖRKENHEIM, J.M.: Operative treatment of type C intercondylar fractures of the distal humerus: results after a mean follow-up of 2 years in a series of 18 patients. Shoulder Elbow Surg., 11: 48-52, 2002. Přejít k původnímu zdroji... Přejít na PubMed...
  18. PERELES, T.R., KOVAL, K.J., GALLAGHER, M., ROSEN, H.: Open reduction and internal fixation of the distal humerus: functional outcome in the elderly. J. Trauma, 43: 578-584, 1997. Přejít k původnímu zdroji... Přejít na PubMed...
  19. REISING, K., HAUSCHILD, O., STROHM, P.C., SUEDKAMP, N.P: Stabilisation of articular fractures of the distal humerus: early experience with a novel perpendicular plate system. Injury, 40: 611-617, 2009. Přejít k původnímu zdroji... Přejít na PubMed...
  20. RING, D., JUPITER, J.B., GULOTTA, L.: Articular fractures of the distal part of the humerus. J. Bone Jt Surg., 85-A: 232-238, 2003. Přejít k původnímu zdroji... Přejít na PubMed...
  21. RUAN, H.J., LIU, J.J., FAN, C.Y., JIANG, J., ZENG, B.F.: Incidence, management, and prognosis of early ulnar nerve dysfunction in type C fractures of distal humerus. J. Trauma, 67: 1397-1401, 2009. Přejít k původnímu zdroji... Přejít na PubMed...
  22. RUEDI, T., MURPHY, WM.: AO Principles of Fracture Management. Vol. 1. Thieme: Stuttgart-New York 2000.
  23. RÜBBERDT, A., SURKE, C., FUCHS, T., FRERICHMANN, U., MATUSZEWSKI, L., VIETH, V., RASCHKE, M.J.: Preformed plate-fixation system for type AO 13C3 distal humerus fractures, Unfallchirurg, 111: 308-322, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  24. SANCHEZ-SOTELO, J., TORCHIA, M.E., O'DRISCOLL, S.W.: Complex distal humeral fractures: internal fixation with a principle-based parallel-plate technique. Surgical technique. J. Bone Jt Surg., 90-A: Suppl 2 Pt 1: 31-46, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  25. SCHUSTER, I., KORNER, J., ARZDORF, M., SCHWIEGER, K., DIEDERICHS, G., LINKE, B.: Mechanical comparison in cadaver specimens of three different 90-degree double-plate osteosyntheses for simulated C2-type distal humerus fractures with varying bone densities. J. Orthop. Trauma, 22: 113-120, 2008. Přejít k původnímu zdroji... Přejít na PubMed...
  26. SRINIVASAN, K., AGARWAL, M., MATTHEWS, S.J., GIANNOUDIS, P.V.: Fractures of the distal humerus in the elderly: is internal fixation the treatment of choice? Clin. Orthop. Relat. Res., 434: 222-230, 2005. Přejít k původnímu zdroji... Přejít na PubMed...
  27. SOON, J.L., CHAN, B.K., LOW, C.O.: Surgical fixation of intraarticular fractures of the distal humerus in adults. Injury, 35: 44-54, 2004. Přejít k původnímu zdroji... Přejít na PubMed...
  28. STOFFEL, K., CUNNEEN, S., MORGAN, R., NICHOLLS, R., STACHOWIAK, G.J.: Comparative stability of perpendicular versus parallel double-locking plating systems in osteoporotic comminuted distal humerus fractures. Orthop. Res., 26: 778-784. 2008. Přejít k původnímu zdroji... Přejít na PubMed...