Acta Chir Orthop Traumatol Cech. 2013; 80(1):89-91 | DOI: 10.55095/achot2013/014

Alternative Technique of Cement Augmentation of Loosened Pedicle Screws - Technical Note and Presentation of Two CasesCase report

T. Kocak*, M. Däxle, H. Reichel, F. Lattig
Department of Orthopaedic Surgery, University of Ulm, Germany

An alternative cement augmentation technique for pedicle screws is described, which was applied in two patients with mono- and bisegmental non-union after preceding multisegmental lumbar fusion. The correctly placed pedicle screws in S1 with diameters of 6 and 8.5 mm had severely enlarged the screw cavities due to segmental instability. Revision screws with 10 mm diameter demonstrated sufficient purchase only on the left side. Therefore, cement augmentation was performed for the right sided screws. After verification of intact pedicle borders, the cavity was filled up with PMMA bone cement. Afterwards, a Kirschner wire was positioned centrally, the hardening of the cement was awaited, the cement was gradually drilled and the screw was placed. In both patients, sufficient purchase of the cemented pedicle screws was documented. Screw insertion after awaiting the hardening of the bone cement in pedicles and vertebral bodies with huge defect situations seems to be an alternative to previous cement augmentation techniques of pedicle screws with the advantage, that the screws could be more easily unscrewed, if necessary.

Keywords: bone cement, augmentation, pedicle screws, revision, spondylodesis

Published: February 1, 2013  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Kocak T, Däxle M, Reichel H, Lattig F. Alternative Technique of Cement Augmentation of Loosened Pedicle Screws - Technical Note and Presentation of Two Cases. Acta Chir Orthop Traumatol Cech. 2013;80(1):89-91. doi: 10.55095/achot2013/014. PubMed PMID: 23452428.
Download citation

References

  1. BOSTAN, B., ESENKAYA, I., GUNES, T., ERDEM, M., ASCI, M., KELESTEMUR, M. H., SEN, C.: A biomechanical comparison of polymethylmethacrylate-reinforced and expansive pedicle screws in pedicle-screw revisions. Acta Orthop. Traumatol. Turc., 43: 272-276, 2009. Go to original source... Go to PubMed...
  2. BULLMANN, V., LILJENQVIST, U. R., RÖDL, R., SCHULTE, T. L.: Pedicle screw augmentation from a biomechanical view. Orthopade, 39: 673-678, 2010. Go to original source... Go to PubMed...
  3. BULLMANN, V., SCHMOELZ, W., RICHTER, M., GRATHWOHL, C., SCHULTE, T. L.: Revision of cannulated and perforated cement-augmented pedicle screws: a biomechanical study in human cadavers. Spine, 35: E932-939, 2010. Go to original source... Go to PubMed...
  4. BURVAL, D. J., MCLAIN, R. F., MILKS, R., INCEOGLU, S.: Primary pedicle screw augmentation in osteoporotic lumbar vertebrae: biomechanical analysis of pedicle fixation strength. Spine, 32: 1077-1083, 2007. Go to original source... Go to PubMed...
  5. CHANG, M. C., LIU, C. L., CHEN, T. H.: Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery: a novel technique. Spine, 33: 317-324, 2008. Go to original source... Go to PubMed...
  6. COOK, S. D., SALKELD, S. L., STANLEY, T., FACIANE, A., MILLER, S. D.: Biomechanical study of pedicle screw fixation in severely osteoporotic bone. Spine J., 4: 402-408, 2004. Go to original source... Go to PubMed...
  7. COOK, S. D., SALKELD, S. L., WHITECLOUD, T. S. 3rd, BARBERA, J.: Biomechanical evaluation and preliminary clinical experience with an expansive pedicle screw design. J. Spinal Disord., 13: 230-236, 2000. Go to original source... Go to PubMed...
  8. FRANKEL, B. M., D'AGOSTINO, S., WANG, C.: A biomechanical cadaveric analysis of polymethylmethacrylate-augmented pedicle screw fixation. J. Neurosurg. Spine, 7: 47-53, 2007. Go to original source... Go to PubMed...
  9. KINER, D. W., WYBO, C. D., STERBA, W., YENI, Y. N., BARTOL, S. W., VAIDYA, R.: Biomechanical analysis of different techniques in revision spinal instrumentation: larger diameter screws versus cement augmentation. Spine, 33: 2618-2622, 2008. Go to original source... Go to PubMed...
  10. POLLY, D. W. JR., ORCHOWSKI, J. R., ELLENBOGEN, R. G.: Revision pedicle screws. Bigger, longer shims-what is best? Spine, 23: 1374-1379, 1998. Go to original source... Go to PubMed...