Acta Chir Orthop Traumatol Cech. 2013; 80(3):203-207 | DOI: 10.55095/achot2013/032

Long-Term Results of Nailing of Extra-Articular Proximal Humerus FracturesOriginal papers

M. KLOUB1,*, K. HOLUB1, P. KOPAČKA1, V. D®UPA2
1 Oddělení úrazové chirurgie Nemocnice České Budějovice
2 Ortopedicko-traumatologická klinika 3. lékařské fakulty Univerzity Karlovy a Fakultní nemocnice Královské Vinohrady, Praha

PURPOSE OF THE STUDY:
To evaluate the long-term results of intramedullary nailing of extra-articular proximal humerus fractures.

MATERIAL AND METHODS:
Thirty-six patients with 36 extra-articular fractures, types 11-A2 and 11-A3, treated by intramedullary nailing were reassessed after an average follow-up of 54 (30-86) months. The group included five type 11-A2 and 31 type 11-A3 fractures according to the AO/OTA classification. Radiographic and clinical outcomes - the absolute Constant score (CSabs) and the relative Constant score (compared to the contralateral side, CSrel) were evaluated. The rate of complications was assessed.

RESULTS:
All fractures healed. The mean long-term CSabs was 73 pts, the mean CSrel was 89% of the unaffected side. Thirty (83%) patients achieved excellent or good results (CSrel higher than 80%), four (11%) had satisfactory and two patients (5.5%) had poor results (CSrel less than 60%). No significant difference was observed in functional results between different age groups. No non-union, loss of reduction or deep infection was encountered. Two cases of prolonged healing were observed, one implant-related complication happened due to locking screw breakage.
Conclusion
Nailing can be recommended for the safe treatment of extra-articular fractures of the proximal humerus. If the procedure is performed properly, the possibility of excellent functional results is high and the rate of complications is minimal. Age does not influence the final functional result.

Keywords: proximal humerus, extra-articular fractures, intramedullary nail, long-term results

Published: June 1, 2013  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
KLOUB M, HOLUB K, KOPAČKA P, D®UPA V. Long-Term Results of Nailing of Extra-Articular Proximal Humerus Fractures. Acta Chir Orthop Traumatol Cech. 2013;80(3):203-207. doi: 10.55095/achot2013/032. PubMed PMID: 23777945.
Download citation

References

  1. AGUDELO, J., SCHÜRMANN, M., STAHEL, P., HELWIG, P., MORGAN, S. J., ZECHEL, W., BAHRS, C., PAREKH, A., ZIRAN, B., WILLIAMS, A., SMITH, W.: Analysis of efficacy and failure in proximal humerus fractures treated with locking plates. J. Orthop. Trauma, 21: 676-681, 2007. Go to original source... Go to PubMed...
  2. BLUM, J., HANSEN, M., ROMMENS, P. M.: Die winkelstabile Marknagelung bei Frakturen am proximalen Humerus mit dem PHN. Oper. Orthop. Traumatol., 21: 296-311, 2009. Go to original source... Go to PubMed...
  3. CONSTANT, C. R., MURLEY, A. H.: A clinical method of functional assessment of the shoulder. Clin. Orthop. Relat. Res., 214: 160-164, 1987. Go to original source...
  4. FJALESTAD, T., HOLE, M. Ø., BLÜCHER, J., HOVDEN, I. A., STIRIS, M. G., STRØMSØE, K.: Rotator cuff tears in proximal humeral fractures: an MRI cohort study in 76 patients. Arch. Orthop. Trauma Surg., 130: 575-581, 2010. Go to original source... Go to PubMed...
  5. FÜCHTMEIER, B., MAY, R., HENTE, R., MAGHSUDI, M., VÖLK, M., HAMMER, J., NERLICH, M., PRANTL, L.: Proximal humerus fractures: a comparative biomechanical analysis of intra and extramedullary implants. Arch. Orthop. Trauma Surg., 127: 441-447, 2007. Go to original source... Go to PubMed...
  6. GARDNER, M. J., BORAIAH, S., HELFET, D. L., LORICH, D. G.: The anterolateral acromial approach for fractures of the proximal humerus. J. Orthop. Trauma, 22: 132-137, 2008. Go to original source... Go to PubMed...
  7. GIERER, P., SCHOLZ, M., BECK, M., SCHASER, K. D., VOLLMAR, B., MITTLMEIER, T., GRADL, G.: Microcirculatory sequellae of the rotator cuff after antegrade nailing in proximal humeral fracture. Arch. Orthop. Trauma Surg., 130: 687-691, 2010. Go to original source... Go to PubMed...
  8. GRADL, G., DIETZE, A., KÄÄB, M., HOPFENMÜLLER, W., MITTLMEIER, T.: Is locking nailing of humeral head fractures superior to locking plate fixation? Clin. Orthop. Relat. Res., 467: 2986-2993, 2009. Go to original source... Go to PubMed...
  9. GREINER, S., KÄÄB, M. J., HAAS, N. P., BAIL, H. J.: Humeral head necrosis rate at mid-term follow-up after open reduction and angular stable plate fixation for proximal humeral fractures. Injury, 40: 186-191, 2009. Go to original source... Go to PubMed...
  10. HELWIG, P., BAHRS, C., EPPLE, B., OEHM, J., EINGARTNER, C., WEISE, K.: Does fixed-angle plate osteosynthesis solve the problems of a fractured proximal humerus? A prospective series of 87 patients. Acta Orthop., 80: 92-96, 2009. Go to original source... Go to PubMed...
  11. HESSMANN, M. H., ROMMENS, P. M.: Osteosynthesetechniken bei proximalen Humerusfrakturen. Chirurg, 72: 1235-1245, 2001. Go to original source... Go to PubMed...
  12. HESSMANN M. H., HANSEN, W. S., KRUMMENAUER, F., POL, T. F., ROMMENS, P.: Locked plate fixation and intramedullary nailing for proximal humeral fractures: a biomechanical evaluation. J. Trauma, 58: 1194-1201, 2005. Go to original source... Go to PubMed...
  13. HORN, J., GUEORGUEIV, B., BRIANZA, S., STEEN, H., SCHWIEGER, K.: Biomechanical evaluation of two-part surgical neck fractures of the humerus fixed by an angularstable locked intramedullary nail. J. Orthop. Trauma, 25: 406-413, 2011. Go to original source... Go to PubMed...
  14. JOST, B., SPROSS, C., GREHN, H., GERBER, C.: Locking plate fixation of fractures of the proximal humerus: analysis of complications, revision strategies and outcome. J. Shoulder Elbow Surg., Sep 6. [Epub ahead of print], 2012. Go to original source... Go to PubMed...
  15. KITSON, J., BOOTH, G., DAY, R.: A biomechanical comparison of locking plate and locking nail implants used f or fractures of the proximal humerus. J. Shoulder Elbow Surg., 16: 362-366, 2007. Go to original source... Go to PubMed...
  16. KRAPPINGER, D., BIZZOTTO, N., RIEDMANN, S., KAMMERLANDER, C., HENGG, C., KRALINGER, F. S.: Predicting failure after surgical fixation of proximal humerus fractures. Injury, 42: 1283-1288, 2011. Go to original source... Go to PubMed...
  17. KŘIVOHLÁVEK, M., LUKÁ©, R., TALLER, S., ©RÁM, J.: Pouľití úhlově stabilních implantátů při oąetření zlomenin proximálního humeru: prospektivní studie. Acta Chir. orthop. Traum. čech., 75: 212-220, 2008. Go to original source...
  18. LIHNART, W., UEBLACKER, P., GROSSTERLINDEN, L., KSCHOWAK, P., BRIEM, D., JANSSEN, A., HASSUNIDAZEH, B., SCHINKE, M.,WINDOLF, J., RUEGER, J. M.: Antegrade nailing of humeral head fractures with captured interlocking screws. J. Orthop. Trauma, 21: 285-294, 2007.
  19. MATHEWS, J., LOBENHOFFER, P.: Marknagelung instabiler proximaler Humerusfrakturen. Oper. Orthop. Traumatol., 19: 255-275, 2007. Go to original source... Go to PubMed...
  20. MICIC, I. D., KIM, K. C., SHIN, D. J., SHIN, S. J., KIM, P. T., PARK, I. H., JEON, I. H.: Analysis of early failure of the locking compression plate in osteoporotic proximal humerus fractures. J. Orthop. Sci., 14: 596-601, 2009. Go to original source... Go to PubMed...
  21. MITTLMEIER, T. W., STEDTFELD, H. W., EWERT, A., BECK, M., FROSCH, B., GRADL, G.: Stabilization of proximal humeral fractures with an angular and sliding stable antegrade locking nail. J. Bone Jt Surg., 85-A (Suppl 4): 136-146, 2003. Go to original source... Go to PubMed...
  22. RÖDERER, G., ERHARDT, J., KUSTER, M., VEGT, P., BAHRS, C., KINZL, L., GEBHARD, F.: Second generation locked plating of proximal humerus fractures - a prospective multicentre observational study. Int. Orthop., 35: 425-432, 2011. Go to original source... Go to PubMed...
  23. YOUNG, A. A., HUGHES, J. S.: Locked intramedullary nailing for treatment of displaced proximal humerus fractures. Orthop. Clin. N. Am., 39: 417-428, 2008. Go to original source... Go to PubMed...
  24. ZHU, Y., LU, Y., SHEN, J., ZHANG, J., JIANG, CH.: Locking intramedullary nails and locking plates in the treatment of two-part proximal humeral surgical neck fractures. J. Bone Jt Surg., 93-A: 159-168, 2011. Go to original source... Go to PubMed...