PURPOSE OF THE STUDY:
The aim of our study is to investigate the reliabilities of the radiographic union score for tibial fracture (RUST) and modified RUST scoring systems in the evaluation of fracture healing in adult tibia fractures treated with intramedullary nailing and pediatric tibia fractures treated with closed reduction and cast immobilization and to compare the reliabilities between two groups.

MATERIAL AND METHODS:
Between January 2016 and January 2020, the informations of patients (ages of 4-10) with tibia fractures treated with closed reduction and casting and patients (aged 18-65 years) with tibia fractures treated with intramedullary nailing were analyzed retrospectively. Forty-seven good quality AP and lateral radiographs (represent different healing stages) each for pediatric and adult fracture groups were selected and were included in two PPTs separately. The radiographs were assessed twice with an interval of three weeks by an observer group consisting of four senior orthopedic surgeons and four orthopedic residents, and fractures were evaluated according to the RUST and mRUST scoring systems.

RESULTS:
The inter-observer agreement of RUST and mRUST were 'perfect' in adult tibia fractures and 'substantial' in pediatric tibia fractures in both evaluations. However, in deciding fracture consolidation, inter-observer agreement was found to be 'perfect' in pediatric tibia fractures, while it was 'substantial' in adult fractures in both assessments. The mean intra-observer reliability of RUST system in adult tibia fractures was 0.860 (0.674-0.968) and 0.818 (0.693-0.909) in pediatric tibia fractures, respectively. The mean intra-observer agreement of mRUST system was 0.842(0.745-0.979) in adult fractures and 0.857 (0.756-0.932) in pediatric fractures, respectively. The mean intra-observer reliability of decision on union was 0.842 (0.638-1.000) in adult fractures and 0.785 (0.611-0.977) in pediatric fractures, respectively.

DISCUSSION:
The decision of union in tibia shaft fractures is based on repeated clinical and radiological evaluations but there are no universally accepted guidelines to evaluate radiographic union. It has been shown in previous studies that the RUST and mRUST scoring systems can be used safely in the evaluation of fracture healing in adult patients with tibia fracture treated with intra-medullary nailing. To our knowledge, there are no studies investigating the reliability of RUST and mRUST systems in conservatively treated pediatric tibial fractures. We hypothesized that the plaster of Paris makes it difficult to assess fracture union on direct radiographs and reduce the reliabilities of these scoring systems in pediatric tibial fractures.

CONCLUSIONS:
Our study showed that both RUST and mRUST scoring systems are useful tools that can be used safely assessing fracture healing in both pediatric and adult tibia fractures. The presence of a plaster of Paris on the extremity did not adversely affect the inter-observer and intra-observer agreement of the RUST and mRUST scoring systems.

Klíčová slova: pediatric tibia fracture, radiographic union score for tibial fracture (RUST), modified RUST, radiographic union, reliability

Zveřejněno: 15. červen 2021  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
KUMBARACI M, TURGUT A, HANCIOGLU S, GUNAY H, ALTUNDAG U, EGELI E. Vliv sádrového obvazu na spolehlivost RUST a mRUST skórovacích systémů. Acta Chir Orthop Traumatol Cech. 2021;88(3):222-228. doi: 10.55095/achot2021/035. PubMed PMID: 34228619.
Stáhnout citaci

Reference

  1. Bhandari M, Guyatt GH, Swiontkowski MF, Tornetta P 3rd, Sprague S, Schemitsch EH. A lack of consensus in the assessment of fracture healing among orthopaedic surgeons. J Orthop Trauma. 2002;16:562-566. Přejít k původnímu zdroji... Přejít na PubMed...
  2. Brinker MR, Bailey DE, Jr. Fracture healing in tibia fractures with an associated vascular injury. J Trauma. 1997;42:11-19. Přejít k původnímu zdroji... Přejít na PubMed...
  3. Cekic E, Alici A, Yeşil M. Reliability of the radiographic union score for tibial fractures. Acta Orthop Traumatol Turc. 2014;48:533-540. Přejít k původnímu zdroji... Přejít na PubMed...
  4. Cooke ME, Hussein AI, Lybrand KE, Wulff A, Simmons E, Choi JH, Litrenta J, Ricci WM, Nascone JW, O'Toole RV, Morgan EF, Gerstenfeld LC, Tornetta P 3rd. Correlation between RUST assessments of fracture healing to structural and biomechanical properties. J Orthop Res. 2018;36:945-953. Přejít k původnímu zdroji... Přejít na PubMed...
  5. Craig JG, Jacobson JA, Moed BR. Ultrasound of fracture and bone healing. Radiol Clin North Am. 1999;37:737-751. Přejít k původnímu zdroji... Přejít na PubMed...
  6. Fleiss JL. Statistical methods for rates and proportions. 2nd ed., John Wiley & Sons, New York, 1981.
  7. Fowler J, Dubina AG, Castillo RC, Boulton CL, Nascone JW, Sciadini MF, et al. Prediction of tibial nonunions at 3 months after intramedullary nailing. Presented at the Annual Meeting of the Orthopaedic Trauma Association, October 2014.
  8. Hammer RR, Hammerby S, Lindholm B. Accuracy of radiologic assessment of tibial shaft fracture union in humans. Clin Orthop Relat Res. 1985;199:233-238. Přejít k původnímu zdroji...
  9. Hogue GD, Wilkins KE, Kim IS. Management of Pediatric Tibial Shaft Fractures. J Am Acad Orthop Surg. 2019;27:769-778. Přejít k původnímu zdroji... Přejít na PubMed...
  10. Kooistra BW, Dijkman BG, Busse JW, Sprague S, Schemitsch EH, Bhandari M. The radiographic union scale in tibial fractures: reliability and validity. J Orthop Trauma 2010;24(Suppl 1):S81-86. Přejít k původnímu zdroji... Přejít na PubMed...
  11. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33:159-174). Přejít k původnímu zdroji... Přejít na PubMed...
  12. Leow JM, Clement ND, Tawonsawatruk T, Simpson CJ, Simpson AHRW. The radiographic union scale in tibial (RUST) fractures: reliability of the outcome measure at an independent centre. Bone Joint Res. 2016;5:116-121. Přejít k původnímu zdroji... Přejít na PubMed...
  13. Litrenta J, Tornetta P 3rd, Mehta S, Jones C, OʼToole RV, Bhandari M, Kottmeier S, Ostrum R, Egol K, Ricci W, Schemitsch E, Horwitz D. Determination of radiographic healing: an assessment of consistency using RUST and modified RUST in metadiaphyseal fractures. J OrthopTrauma. 2015;29:516-520. Přejít k původnímu zdroji... Přejít na PubMed...
  14. Litrenta J, Tornetta P 3rd, Ricci W, Sanders RW, OʼToole RV, Nascone JW, Faber H, Wilson D. In vivo correlation of radiographic scoring (radiographic union scale for tibia fractures) and biomechanical data in a sheep osteotomy model: can we define union radiographically? Orthop Trauma. 2017;31:127-130. Přejít k původnímu zdroji...
  15. Martin J Herman, Melissa A Martinek, Joshua M Abzug. Complications of tibial eminence and diaphyseal fractures in children: prevention and treatment. Instr Course Lect. 2015;64:471-482. Přejít na PubMed...
  16. Raducha JE, Swarup I, Schachne JM, Cruz AI Jr, Fabricant PD. tibial shaft fractures in children and adolescents. JBJS Rev. 2019;7:e4. Přejít k původnímu zdroji... Přejít na PubMed...
  17. Ross KA, O'Halloran K, Castillo RC, Coale M, Fowler J, Nascone JW, Sciadini MF, LeBrun CT, Manson TT, Carlini AR, Jolissaint JE, O'Toole RV. Prediction of tibial nonunion at the 6-week time point. Injury. 2018;49:2075-2082. Přejít k původnímu zdroji... Přejít na PubMed...
  18. Sarmiento A, Sobol PA, Sew Hoy AL, Ross SD, Racette WL, Tarr RR. Prefabricated functional braces for the treatment of fractures of the tibial diaphysis. J Bone Joint Surg Am. 1984;66:1328-1339. Přejít k původnímu zdroji... Přejít na PubMed...
  19. Schnarkowski P, Re'die J, Peterfy CG, Weidenmaier W, Mutschler W, Arand M, Reiser MF. Tibial shaft fractures: assessment of fracture healing with computed tomography. J Comput Assist Tomogr. 1995;19:777-781. Přejít k původnímu zdroji...
  20. Schwarz O, Majerníček M, Chomiak J. [Treatment of Fractures of the Distal Third of Tibia Diaphysis by MIPO Technique]. Acta Chir Orthop Traumatol Cech. 2020;87:114-119. Přejít k původnímu zdroji... Přejít na PubMed...
  21. Tower SS, Beals RK, Duwelius PJ. Resonant frequency analysis of the tibia as a measure of fracture healing. J Orthop Trauma. 1993;7:552-557. Přejít k původnímu zdroji... Přejít na PubMed...
  22. Whelan DB, Bhandari M, Stephen D, Kreder H, McKee MD, Zdero R, Schemitsch EH. Development ofthe radiographic union score for tibial fractures forthe assessment of tibial fracture healing after intramedullary fixation. J Trauma. 2010;68:629-632. Přejít k původnímu zdroji... Přejít na PubMed...