Acta Chir Orthop Traumatol Cech. 2023; 90(1):34-40 | DOI: 10.55095/achot2023/005

Nejlepší řešení pro dosažení maximální komprese fragmentů u zlomenin skafoidea - jeden nebo dva Herbertovy šrouby?Původní práce

L. SIMEONOV
Division of Hand and Microsurgery, University Hospital of Emergency Medicine, Sofia, Bulgaria

PURPOSE OF THE STUDY:
To compare the treatment outcome of scaphoid facture fixation with one versus two Herbert screws (HBS).

MATERIAL AND METHODS:
72 patients underwent open reduction internal fixation (ORIF) following acute scaphoid fracture, and were followed prospectively by one surgeon. All fractures were Herbert & Fisher classification type B, the most common fracture lines being oblique (n=38) and transverse (n=34). Fractures with similar fracture lines were randomly assigned into two groups; fractures stabilized with one HBS (n=42) and fractures stabilized with two HBS (n=30). A specific methodology was developed for placement of two HBS; in the case of transverse fractures, screws were introduced perpendicular to the fracture line, for oblique fractures the first screw was placed perpendicular to the fracture line and the second screw was placed along the longitudinal axis of the scaphoid.

RESULTS:
Patients were followed for a total 24 months, no patients were lost to follow-up. Outcome measures included bone healing, duration to bone healing, carpal geometry, range of motion (ROM), grip strength, and the Mayo Wrist Score. Patient rated outcomes were measured using DASH. Bone healing was radiographically and clinically confirmed in 70 patients. There were two non-unions after fixation with one HBS. Radiographic angles in both groups did not differ significantly from the physiological values. The mean duration to bone union was 1.8 months for one HBS and 1.5 months for two HBS. Mean grip strength was 47 kg in the group with one HBS (16-70 kg), 94 % of the unaffected hand, and 49 kg in the group with two HBS, 97% unaffected hand. The average Visual Analog Scale (VAS) score for the group with one HBS was 2.5, while for the group with two HBS was 2.0. Both groups had excellent and good results. For the group with two HBS, they are more. (100% for those fixed with two HBS and for those fixed with one HBS = 95% excellent and good and 5% bad results).

DISCUSSION:
A review of the literature confirms that the addition of the second screw increases the stability in the scaphoid fractures by offering added resistance to torque forces. Most authors propose the parallel placing of both screws in all cases. In our study we offer an algorithm for the placement of screws depending of the type of fracture line. For transverse fractures screws are placed parallel and perpendicular to the fracture line, for oblique fractures the first screw is placed perpendicular to the fracture line, and the second screw is placed along the longitudinal axis of the scaphoid. This algorithm covers the main laboratory requirements for maximal fracture compression depending of the fracture line.

CONCLUSIONS:
This study of 72 patients in whom patients with similar fracture geometry were separated into two groups fixed by one HBS and fixed by two HBS. Analysis of the results demonstrate that osteosynthesis with two HBS creates greater fracture stability. The proposed algorithm for fixation of acute scaphoid fractures using two HBS is achieved by simultaneously placing the screw along the axial axis and perpendicular to the fracture line. The stability is improved by the equal distribution of the compression force on the entire fracture surface.

Klíčová slova: scaphoid fractures, Herbert screw, two screws fixation

Zveřejněno: 15. únor 2023  Zobrazit citaci

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
SIMEONOV L. Nejlepší řešení pro dosažení maximální komprese fragmentů u zlomenin skafoidea - jeden nebo dva Herbertovy šrouby? Acta Chir Orthop Traumatol Cech. 2023;90(1):34-40. doi: 10.55095/achot2023/005. PubMed PMID: 36907581.
Stáhnout citaci

Reference

  1. Cooney WP, Bussey R, Dobync JH, Linscheid RL. Difficult wrist fractures and perilunate-fracture dislocations of the wrist. Clin Orthop. 1987;214:136-147. Přejít k původnímu zdroji...
  2. Cooney WP, Dobyns JH, Linscheid RL. Fractures of the scaphoid: a rational approach to management. Clin Orthop Relat Res. 1980;149:90e97. Přejít k původnímu zdroji...
  3. Crawford LA, Eric S. Powell ES, Trail IA. The fixation strength of scaphoid bone screws: an in vitro investigation using polyurethane foam. J Hand Surg. 2012;37A:255-260. Přejít k původnímu zdroji... Přejít na PubMed...
  4. Faucher GD, Golden ML, Sweeney RK, Hutton WC, Claudius D, Jarrett J. Comparison of screw trajectory on stability of oblique scaphoid fractures: a mechanical study. J Hand Surg Am. 2014;39:430-435. Přejít k původnímu zdroji... Přejít na PubMed...
  5. Filan SL, Herbert TJ. Herbert screw fixation of scaphoid fractures. J Bone Joint Surg Br. 1996;78:519-529. Přejít k původnímu zdroji...
  6. Garala K, Taub N, Dias J. The epidemiology of fractures of the scaphoid: impact of age, gender, deprivation and seasonality. Bone Joint J. 2016;98:654-659. Přejít k původnímu zdroji... Přejít na PubMed...
  7. Garciа R, Leversage J, Aldridge M, Richard MJ, Ruch l. Scaphoid nonunions treated with 2 headless compression screws and bone grafting. J Hand Surgery Am. 2014;39:1301-1307. Přejít k původnímu zdroji... Přejít na PubMed...
  8. Gordon PB, Ferreira LF, Johnson JA, Graham J.W, King. Interfragmentary compression across a simulated scaphoid fracture-analysis of 3 screws. J Hand Surg Am. 2004;29:273-278. Přejít k původnímu zdroji... Přejít na PubMed...
  9. Hart A, Mansuri A, Harvey E, Martineau P. Central versus eccentric internal fixation of acute scaphoid fractures. J Hand Surg Am. 2013;38:66-71. Přejít k původnímu zdroji... Přejít na PubMed...
  10. Herbert T, Fisher W. Management of the fractured scaphoid using a new bone screw. J Bone Joint Surg Br. 1984;66:114-123. Přejít k původnímu zdroji... Přejít na PubMed...
  11. Jurkowitsch, Dall'Ara E, Quadlbauer S, Pezzei C, Jung I, Pahr D, Leixnering M. Rotational stability in screw-fixed scaphoid fractures compared to plate-fixed scaphoid fractures. Arch Orthop Trauma Surg. 2016;136:1623-1628. Přejít k původnímu zdroji... Přejít na PubMed...
  12. Kawamura K, Chung K. Treatment of scaphoid fractures and nonunions. J Hand Surg Am. 2008;33:988-997. Přejít k původnímu zdroji... Přejít na PubMed...
  13. Luria S, Hoch S, Liebergall M, Mosheiff R, Peleg E. Optimal fixation of acute scaphoid fractures: finite element analysis. J Hand Surg Am. 2010;35:1246-1250. Přejít k původnímu zdroji... Přejít na PubMed...
  14. Mandaleson A, Tham S, Lewis C, Ackland D, Ek E. Scaphoid fracture fixation in a nonunion model: a biomechanical study comparing 3 types of fixation. J Hand Surg Am. 2018;43:221-228. Přejít k původnímu zdroji... Přejít na PubMed...
  15. McCallister WV, Knight J, Kaliappan R, Trumble TE. Central placement of the screw in simulated fractures of the scaphoid waist: a biomechanical study. J Bone Joint Surg Am. 2003;85:72-77. Přejít k původnímu zdroji... Přejít na PubMed...
  16. Moojen TM, Snel JG, Ritt MJPF, Venema HW, Kauer JMG, Bos KE. Scaphoid kinematics in vivo. J Hand Surg Am. 2002;27:1003-1010). Přejít k původnímu zdroji... Přejít na PubMed...
  17. Quadlbauer S, Beer T, Pezzei C, Jurkowitsch J, Tichy A, Hausner T, Leixnering M. Stabilization of scaphoid type B2 fractures with one or two headless compression screws. Arch Orthop Trauma Surg. 2017;137:1587-1595. Přejít k původnímu zdroji... Přejít na PubMed...
  18. Sabbagh M, Morsy M, Moran S. Diagnosis and management of acute scaphoid fractures. Hand Clin. 2019;35:259-269. Přejít k původnímu zdroji... Přejít na PubMed...
  19. Simeonov L. Jacobson P. Clinical and self-report outcome measurement systems for the wrist and hand: current concepts. Orthop Trauma. 2013;4:188-200.
  20. Singh H, Taub N, Dias J. Management of displaced fractures of the waist of the scaphoid: meta-analyses of comparative studies. Injury. 2012;43:933-939. Přejít k původnímu zdroji... Přejít na PubMed...
  21. Slade J, Merrell G. Minimally invasive management of scaphoid fractures. Oper Tech Plast Reconstr Surg. 2002;9:143-150. Přejít k původnímu zdroji...
  22. Surke C, Lachlan S, Xin Zhang, Ek E, Ackland D, Tham S. J Double-screw osteosynthesis in an unstable scaphoid fracture model: a biomechanical comparison of two screw configurations. J Hand Surg Am. Epub 2021 Oct. 2022;47:1118.e1-1118.e8. Přejít k původnímu zdroji... Přejít na PubMed...
  23. Yildirim B, Nicole D, Chhabra B. Two-screw fixation of scaphoid waist fractures. J Hand Surg Am. 2020;45:783.e1-783.e4. Přejít k původnímu zdroji... Přejít na PubMed...